Research article

Pilot study of pressure-flow properties in a numerical model of the middle ear

  • Received: 10 November 2019 Accepted: 04 February 2020 Published: 17 February 2020
  • BackgroundConstructing a three-dimensional (3D) model through non-invasive techniques will greatly benefit the diagnosis and treatment of otitis media. However, such a model should reflect the physiological characteristics of the middle ear; in particular, the pressure-flow responses determine the validity of the model.
    ObjectivesA 3D model of the middle ear was constructed by digital scanning and simulation. The pressure-flow properties in the model were measured to evaluate whether the model could reflect the real middle ear under physiological and pathological conditions.
    Materials and methodsComputed tomography (CT) scanning data from a healthy woman were input into Mimics 20.0 to construct 3D images of the middle ear. The 3D images were treated with Ansys 15.0 for finite element mesh generation. Msc Nastran 2014 were used for the fluid-solid coupling calculations.
    ResultsThe pressure-flow rate in the model resembled a Venturi tube, namely, the pressure decreased with increasing flow velocity, especially in the Eustachian tube. In the absence of the right mastoid process, the differences in air pressure and the maximal velocity in the model were reduced.
    ConclusionsThis numerical model based on CT images of the middle ear recapitulates the biomechanical characteristics of the real middle ear.
    SignificanceThis study provides an easy and rapid approach to constructing a middle ear model for diagnosis and treatment of otitis media.

    Citation: Xu Bie, Yuanyuan Tang, Ming Zhao, Yingxi Liu, Shen Yu, Dong Sun, Jing Liu, Ying Wang, Jianing Zhang, Xiuzhen Sun. Pilot study of pressure-flow properties in a numerical model of the middle ear[J]. Mathematical Biosciences and Engineering, 2020, 17(3): 2418-2431. doi: 10.3934/mbe.2020131

    Related Papers:

    [1] Hsiu-Chuan Wei . Mathematical modeling of ER-positive breast cancer treatment with AZD9496 and palbociclib. AIMS Mathematics, 2020, 5(4): 3446-3455. doi: 10.3934/math.2020223
    [2] Inmaculada Galván-Sánchez, Alexis J. López-Puig, Margarita Fernández-Monroy, Sara M. González-Betancor . The mediating role of mathematical literacy in first-year educational outcomes in Business Administration and Management degrees: A gender-based analysis. AIMS Mathematics, 2024, 9(11): 29974-29999. doi: 10.3934/math.20241448
    [3] Shristi Mishra, Harish Nagar, Naveen Mani, Rahul Shukla . NE transform of pathway fractional integrals involving -function. AIMS Mathematics, 2025, 10(2): 3013-3024. doi: 10.3934/math.2025140
    [4] Sumiya Nasir, Nadeem ul Hassan Awan, Fozia Bashir Farooq, Saima Parveen . Topological indices of novel drugs used in blood cancer treatment and its QSPR modeling. AIMS Mathematics, 2022, 7(7): 11829-11850. doi: 10.3934/math.2022660
    [5] Abdur Rehman, Muhammad Zia Ur Rahman, Asim Ghaffar, Carlos Martin-Barreiro, Cecilia Castro, Víctor Leiva, Xavier Cabezas . Systems of quaternionic linear matrix equations: solution, computation, algorithm, and applications. AIMS Mathematics, 2024, 9(10): 26371-26402. doi: 10.3934/math.20241284
    [6] Arsalan D. Mizhidon . A generalized mathematical model for a class of mechanical systems with lumped and distributed parameters. AIMS Mathematics, 2019, 4(3): 751-762. doi: 10.3934/math.2019.3.751
    [7] Valeriy Rozenberg . On a problem of dynamical input reconstruction for a system of special type under conditions of uncertainty. AIMS Mathematics, 2020, 5(5): 4108-4120. doi: 10.3934/math.2020263
    [8] Irina Volinsky, Svetlana Bunimovich-Mendrazitsky . Mathematical analysis of tumor-free equilibrium in BCG treatment with effective IL-2 infusion for bladder cancer model. AIMS Mathematics, 2022, 7(9): 16388-16406. doi: 10.3934/math.2022896
    [9] Julian Osorio, Carlos Trujillo, Diego Ruiz . Construction of a cryptographic function based on Bose-type Sidon sets. AIMS Mathematics, 2024, 9(7): 17590-17605. doi: 10.3934/math.2024855
    [10] A. M. Mishra, D. Kumar, S. D. Purohit . Unified integral inequalities comprising pathway operators. AIMS Mathematics, 2020, 5(1): 399-407. doi: 10.3934/math.2020027
  • BackgroundConstructing a three-dimensional (3D) model through non-invasive techniques will greatly benefit the diagnosis and treatment of otitis media. However, such a model should reflect the physiological characteristics of the middle ear; in particular, the pressure-flow responses determine the validity of the model.
    ObjectivesA 3D model of the middle ear was constructed by digital scanning and simulation. The pressure-flow properties in the model were measured to evaluate whether the model could reflect the real middle ear under physiological and pathological conditions.
    Materials and methodsComputed tomography (CT) scanning data from a healthy woman were input into Mimics 20.0 to construct 3D images of the middle ear. The 3D images were treated with Ansys 15.0 for finite element mesh generation. Msc Nastran 2014 were used for the fluid-solid coupling calculations.
    ResultsThe pressure-flow rate in the model resembled a Venturi tube, namely, the pressure decreased with increasing flow velocity, especially in the Eustachian tube. In the absence of the right mastoid process, the differences in air pressure and the maximal velocity in the model were reduced.
    ConclusionsThis numerical model based on CT images of the middle ear recapitulates the biomechanical characteristics of the real middle ear.
    SignificanceThis study provides an easy and rapid approach to constructing a middle ear model for diagnosis and treatment of otitis media.




    [1] K. J. Kvaerner, P. Nafstad, J. J. K. Jaakkola, Upper respiratory morbidity in preschool children: A cross-sectional study, Arch. Otolaryngol. Head Neck Surg., 126 (2000), 1201-1206.
    [2] C. D. Bluestone, J. O. Klein, Physiology, pathophysiology and pathogenesis, Otitis Media Infants Child., 2 (2007), 17-38.
    [3] R. W. Ranakusuma, Y. Pitoyo, E. D. Safitri, S. Thorning, E. M. Beller, S. Sastroasmoro, et al., Systemic corticosteroids for acute otitis media in children, Cochrane Database Syst. Rev., 3 (2018), CD012289.
    [4] D. S. Hurst, The role of allergy in otitis media with effusion, Otolaryngol. Clin. North Am., 44 (2011), 637-654.
    [5] L. H. Nguyen, J. J. Manoukian, S. E. Sobol, D. S. Melvin, Similar allergic inflammation in the middle ear and the upper airway: evidence linking otitis media with effusion to the united airways concept, J. Allergy Clin. Immunol., 114 (2004), 1110-1115.
    [6] M. E. Smith, J. R. Tysome, Tests of Eustachian tube function: a review, Clin. Otolaryngol., 40 (2015), 300-311.
    [7] M. E. Smith, D. J. Scoffings, J. R. Tysome, Imaging of the Eustachian tube and its function: A systematic review, Neuroradiology, 58 (2016), 543-556.
    [8] A. Teymoortash, S. Hamzei, T. Murthum, B. Eivazi, I. Kureck, J. A. Werner, Temporal bone imaging using digital volume tomography and computed tomography: a comparative cadaveric radiological study, Surg. Radiol. Anat., 33 (2011), 123-128.
    [9] A. Morra, G. Tirelli, A. Rimondini, V. Cioffi, M. Russolo, V. Giacomarra, et al., Usefulness of virtual endoscopic three-dimensional reconstructions of the middle ear, Acta Otolaryngol., 122 (2002), 382-385.
    [10] Z. Csakanyi, G. Katona, E. Josvai, F. Mohos, I. Sziklai, Volume and surface of the mastoid cell system in otitis media with effusion in children: A case-control study by three-dimensional reconstruction of computed tomographic images, Otol. Neurotol., 32 (2011), 64-70.
    [11] J. T. Vrabec, S. W. Champion, J. D. Gomez, R. J. Johnson, G. Chaljub, 3D CT imaging method for measuring temporal bone aeration, Acta Otolaryngol., 122 (2002), 831-835.
    [12] S. Yu, X. Sun, Y. Liu, Numerical Analysis of the Relationship between Nasal Structure and Its Function, Sci. World J., 2014 (2014),1-6.
    [13] X. Sun, C. Yu, Y. Wang, Y. Liu, Numerical simulation of soft palate movement and airflow in human upper airway by fluid-structure interaction method, Acta Mech. Sin., 23 (2007), 359-367.
    [14] Y. Liu, S. Li, X. Sun, Numerical analysis of ossicular chain lesion of human ear, Acta Mech. Sin., 2 (2009), 241-247.
    [15] D. S. Arick, S. Silman, Treatment of otitis media with effusion based on politzerization with an automated device, Ear Nose Throat J., 79 (2000), 290-296.
    [16] J. D. Swarts, S. Foley, C. M. Alper, J. D. William, Mastoid geometry in a cross-section of humans from infancy through early adulthood with a confirmed history of otitis media, Int. J. Pediatr. Otorhinolaryngol., 76 (2012), 137-141.
    [17] G. Volandri, P. F. Di, P. Forte, S. Manetti, Model-oriented review and multi-body simulation of the ossicular chain of the human middle ear, Med. Eng. Phys., 34 (2012), 1339-1355.
    [18] S. N. Ghadiali, J. D. Swarts, W. J. Federspiel, Model-based evaluation of Eustachian tube mechanical properties using continuous pressure-flow rate data, Ann. Biomed. Eng., 30 (2002), 1064-1076.
    [19] F. J. Sheer, J. D. Swarts, S. N. Ghadiali, Three-dimensional finite element analysis of Eustachian tube function under normal and pathological conditions, Med. Eng. Phys., 34 (2012), 605-616.
    [20] M. Sudo, I. Sando, C. Suzuki, Three-dimensional reconstruction and measurement study of human Eustachian tube structures: a hypothesis of Eustachian tube function, Ann. Otol. Rhinol. Laryngol., 107 (1998), 547-554.
  • This article has been cited by:

    1. Jinping Feng, Xinan Zhang, Tianhai Tian, Mathematical Modeling and Inference of Epidermal Growth Factor-Induced Mitogen-Activated Protein Kinase Cell Signaling Pathways, 2024, 25, 1422-0067, 10204, 10.3390/ijms251810204
    2. Alireza Poshtkohi, John Wade, Liam McDaid, Junxiu Liu, Mark L. Dallas, Angela Bithell, Mathematical Modeling of PI3K/Akt Pathway in Microglia, 2024, 36, 0899-7667, 645, 10.1162/neco_a_01643
  • Reader Comments
  • © 2020 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Metrics

Article views(4515) PDF downloads(385) Cited by(4)

Article outline

Figures and Tables

Figures(7)  /  Tables(3)

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return

Catalog