In this paper, a new generalization of the one parameter Rayleigh distribution called the Power Rayleigh (PRD) was employed to model the life of the tested units in the step-stress accelerated life test. Under progressive Type-I interval censored data, the cumulative exposure distribution was considered to formulate the life model, assuming the scale parameter of PRD has the inverse power function at each stress level. Point estimates of the model parameters were obtained via the maximum likelihood estimation method, while interval estimates were obtained using the asymptotic normality of the derived estimators and the bootstrap resampling method. An extensive simulation study of k=4 levels of stress in different combinations of the life test under different progressive censoring schemes was conducted to investigate the performance of the obtained point and interval estimates. Simulation results indicated that point estimates of the model parameters are closest to their initial true values and have relatively small mean squared errors. Accordingly, the interval estimates have small lengths and their coverage probabilities are almost convergent to the 95% significance level. Based on the Fisher information matrix, the D-optimality and the A-optimality criteria are implemented to determine the optimal design of the life test by obtaining the optimum inspection times and optimum stress levels that improve the estimation procedures and give more efficient estimates of the model parameters. Finally, the developed inferential procedures were also applied to a real dataset.
Citation: Hatim Solayman Migdadi, Nesreen M. Al-Olaimat, Omar Meqdadi. Inference and optimal design for the k-level step-stress accelerated life test based on progressive Type-I interval censored power Rayleigh data[J]. Mathematical Biosciences and Engineering, 2023, 20(12): 21407-21431. doi: 10.3934/mbe.2023947
[1] | Peiwen (Perry) Li . Annual Report 2022. AIMS Energy, 2023, 11(1): 135-139. doi: 10.3934/energy.2023007 |
[2] | Peiwen (Perry) Li . Annual Report 2023. AIMS Energy, 2024, 12(1): 271-276. doi: 10.3934/energy.2024013 |
[3] | Akthem Mohi Al-Abdali, Handri Ammari . Thermal energy storage using phase-change material in evacuated-tubes solar collector. AIMS Energy, 2022, 10(3): 486-505. doi: 10.3934/energy.2022024 |
[4] | Badr Ouhammou, Fatima Zohra Gargab, Samir El idrissi kaitouni, Slimane Smouh, Rachid El mrabet, Mohammed Aggour, Abdelmajid Jamil, Tarik Kousksou . Energy saving potential diagnosis for Moroccan university campuses. AIMS Energy, 2023, 11(3): 576-611. doi: 10.3934/energy.2023030 |
[5] | Takvor Soukissian, Anastasios Papadopoulos, Panagiotis Skrimizeas, Flora Karathanasi, Panagiotis Axaopoulos, Evripides Avgoustoglou, Hara Kyriakidou, Christos Tsalis, Antigoni Voudouri, Flora Gofa, Petros Katsafados . Assessment of offshore wind power potential in the Aegean and Ionian Seas based on high-resolution hindcast model results. AIMS Energy, 2017, 5(2): 268-289. doi: 10.3934/energy.2017.2.268 |
[6] | Eduardo Enrique Martinez Jorges, António M.N. Quintino, Diogo M.F. Santos . Economic analysis of lithium-ion battery recycling. AIMS Energy, 2023, 11(5): 960-973. doi: 10.3934/energy.2023045 |
[7] | Majid Deldar, Afshin Izadian, Sohel Anwar . Analysis of a hydrostatic drive wind turbine for improved annual energy production. AIMS Energy, 2018, 6(6): 908-925. doi: 10.3934/energy.2018.6.908 |
[8] | Solomon A. A., Michel Child, Upeksha Caldera, Christian Breyer . Exploiting wind-solar resource complementarity to reduce energy storage need. AIMS Energy, 2020, 8(5): 749-770. doi: 10.3934/energy.2020.5.749 |
[9] | Alemayehu T. Eneyaw, Demiss A. Amibe . Annual performance of photovoltaic-thermal system under actual operating condition of Dire Dawa in Ethiopia. AIMS Energy, 2019, 7(5): 539-556. doi: 10.3934/energy.2019.5.539 |
[10] | Michael O. Dioha, Atul Kumar . Rooftop solar PV for urban residential buildings of Nigeria: A preliminary attempt towards potential estimation. AIMS Energy, 2018, 6(5): 710-734. doi: 10.3934/energy.2018.5.710 |
In this paper, a new generalization of the one parameter Rayleigh distribution called the Power Rayleigh (PRD) was employed to model the life of the tested units in the step-stress accelerated life test. Under progressive Type-I interval censored data, the cumulative exposure distribution was considered to formulate the life model, assuming the scale parameter of PRD has the inverse power function at each stress level. Point estimates of the model parameters were obtained via the maximum likelihood estimation method, while interval estimates were obtained using the asymptotic normality of the derived estimators and the bootstrap resampling method. An extensive simulation study of k=4 levels of stress in different combinations of the life test under different progressive censoring schemes was conducted to investigate the performance of the obtained point and interval estimates. Simulation results indicated that point estimates of the model parameters are closest to their initial true values and have relatively small mean squared errors. Accordingly, the interval estimates have small lengths and their coverage probabilities are almost convergent to the 95% significance level. Based on the Fisher information matrix, the D-optimality and the A-optimality criteria are implemented to determine the optimal design of the life test by obtaining the optimum inspection times and optimum stress levels that improve the estimation procedures and give more efficient estimates of the model parameters. Finally, the developed inferential procedures were also applied to a real dataset.
In recent years, the use of natural gas for power generation, as well as industrial sector consumption has dramatically increased [1,2,3]. Gas pressure boosting stations are used along the transmission lines to supply the required pressure to move from a site to another [4,5,6,7]. On the other hand, due to the pressure constraints of transmission lines, several pressure boosting stations are required for gas transmission across the whole transmission lines [8,9,10]. The locations and pressures required for pressure boosting stations are determined by permissible pressures, available power, and geographical and environmental factors. This is due to the fact that the pressure drop is highly dependent on elevation conditions, which reduces the pressure drop through the gas movement path [11,12,13,14]. Each pressure boosting station consists of several scrubbers to filter the inlet gas, a gas compressor to increase the pressure, and also an air cooler. Indeed, increasing the gas pressure by the compressor causes a rise in gas temperature. The high temperature of the gas necessitates the use of air coolers in the design of pressure boosting stations. Air coolers are among the exchangers that reduce the gas temperature through blowing the air, mostly done by fans, to the tubes carrying high-pressure gas. The cost of generating pressure at a boosting station can be up to 50% of the total gas transportation expenditures [15,16,17,18]. The use of air coolers in gas pressure boosting stations has some disadvantages, such as relatively high-pressure drop and significant power consumption due to the use of electro fans [19,20,21].
Heating pipe is a means of heat transfer, which is now widely used in commercial applications. It is more commonly used as a waste heat recycling device due to bringing high efficiency and low volume without any pollution. Heating pipes usually operate at temperatures ranging from 40 ℃ to 350 ℃. This range can be extended by careful selection of parts of the system. Additionally, the length of individual pipes may vary from a few inches to 5 feet long. Vasiliev and Luikov (2005) investigated a variety of modern heating pipe types. They ultimately concluded that the selection and design of heating pipes required careful consideration of the exact conditions and limitations of the system. It was also stated that heating pipes have different advantages, including high conductivity, isothermal conductivity, low maintenance [22].
Delpach et al. (2019) first addressed the need for energy optimization and its importance in the ceramic furnace sector, which has a substantial consumption share (more than 50% of the total). Also, in the cooling section and to improve the heating recovery, the radiant heating pipe was investigated. Experimental results revealed that the heating pipe could recover the radiant heat and also the natural displacement (About 4 kW) [23]. Ma et al. (2016) discussed the steel industry in China and selected a sample in the melting sector for further investigation. Thermal performance evaluation of heating pipe exchangers has been achieved and analyzed based on heat transfer rate, heat transfer coefficient, energy efficiency and NTU [24]. The results revealed that energy and thermal efficiency has improved and exergy efficiency increased from 34% to 41%. Additionally, by using this system, the heat transfer rate, heat transfer coefficient, and system efficacy rose by 6, 10 and 7%, respectively. In a similar study, Mosleh et al. (2019) investigated the use of pulse heating pipes in the exchanger structure through laboratory works. The results proved that utilizing pulse heating pipes can improve the heat transfer coefficient up to 310%. In their research, R134a operating fluid was used to evaluate the thermal performance of the exchanger. Overall, the authors' studies express that the use of heating pipes, in various sectors of industry and also in building works, significantly contributes to improving efficiency, heat transfer and other relevant indicators [25].
Previous researches have primarily focused on only the application of heat pipes in thermal efficiency and overall heat transfer in different sector such as building and industrial. As mentioned before, air cooler in gas pressure boosting station is an important facility as an energy performance aspect in natural gas increasing pressure process. The other hand, increasing natural gas pressure is the main target in each gas pressure boosting station, and reduce presser drop in air coolers cause to improve energy performance index. Besides, heat transfer can be improved by using heat pipes in the finned tube and cause to decrease the length of the tubes in air cooler with same heat transfer performance. Hence pressure drop can be reduced. Therefore, the loss of pressure and the required power will be reduced, and the efficiency and energy performance index will be improved. To our knowledge, no prior work has been done to assess experimentally in real air cooler size with all limitation at natural gas pressure boosting station.
Recently, different experiences have been studied to use of pulsed heat pipe in different industry. Innovate of this paper is a laboratory system designed by creating similar boundary conditions in natural gas compression station. In natural gas compressor stations industry by use of air coolers, reduce natural gas temperatures, so in this study, similar conditions have been established in the laboratory system as well as laboratory testing at different velocity of inlet fluid, cooling fan system and tubes that no article has been published so far.
In this paper, a laboratory system was first designed and developed to investigate the pressure drop in a tube and then the information and data relevant to a gas pressure boosting station in Iran were gathered and utilized to evaluate two different situations (tubes equipped with finished pipes and also tubes equipped with heating pipes). A case study of a typical gas pressure boosting station shows that under designing conditions, the gas must have a pressure increase of about 1.72 MPa throughout the station, while the triggered pressure drop in the air coolers of the subject station is only 0.2 MPa. In other words, about 11% of the total pressure increased by the gas compressor is lost in the cooling section, which results in lower gas pressure at the next station. Also at the station under study, more than 75% of electrical energy consumption is due to the use of air cooler electro fans at the gas pressure boosting station. Given the importance of increasing the pressure of natural gas at pressure boosting stations, the reduction of energy performance at each station is an objective and indicator of energy performance. In this paper, based on the laboratory and test results, in the designed exchanger, having one tube equipped with pulse heating pipe and another equipped with real-size fins, the effect of pressure drop on energy performance index at different fan speeds was thoroughly discussed and analyzed.
Due to the technical considerations and requirements demanded in this paper, a test system was designed. In the designed device, a fin-equipped tube and also a tube with pulse heating pipes implemented on are used. The purpose of designing such a system is to compare the pressure drop triggered in the fin-equipped tube with the heating-equipped one utilizing R134a operating fluid. For this reason, various equipment was employed to provide real thermodynamic conditions for the internal and external flows of the test tubes. For this purpose, it is necessary to have a system capable of providing process conditions in addition to performing gas cooling to the desired level. Therefore, a system was designed and developed which was capable to initially raise the fluid process temperature to the desired extent and then perform the cooling operation to reach the subject temperature to investigate the pressure drop in various conditions. The axial fan is also used to create external flow. Figure 1 shows the laboratory image of the testing system.
The designed system includes a centrifuge fan equipped with an inverter system to determine the speed of the blown air to create flow inside the pipes. The airflow generated by the centrifuge fan, with 3 kW power and rated 2860 rpm rotation speed, first passes through a box of electric heaters containing twelve 500-watt heating elements and reaches the desired temperature. It should be noted that the heater capacity is variable and can be reached at different temperatures during testing. Each pair of heaters is connected to a switch and can be switched on and off to meet different temperatures of tubes inlet. The hot airflow is then passed through the connections into the inlet header and divided into the internal flow of the pipes. A flow regulating valve is placed on each tube to control the amount of air in each tube and to establish the same conditions through the tubes. Thermocouple K-type thermometer is placed at the beginning and end of the pipes. Ultimately, the airflow passes through the Anemometer flowmeters, Model 6252A, and is discharged into the ambient.
To fill the gas operating fluid, the weight of the test apparatus and the devices attached there are first measured. A weighing scale with 0.05 g accuracy was used to measure weight. To fill the device with R134a gas, both valves are closed first. Then the R134a gas capsule attached to one of the valves with a gas hose. The capsule was placed in a way that it was positioned higher than the upper valve. The capsule is also reversed to place the outlet at the bottom of the device. This is because the R134a liquid is inserted into the outlet of the capsule to fill the heating pipe with this liquid while filling. After the steps as mentioned above, first, we open the capsule valve. Then we open the upper valve of the apparatus and then open the lower one. The gas pressure causes the liquid R134a to fill the oscillating heat pipe and also to expel the air inside the tube. When the liquid R134a is excreted vigorously from the second valve, the second valve closes, and then the first one is shut. The gas hose is slightly loosened to remove the R134a in the hose slowly. The hose is then removed from the device. This method fills the heating pipe with a filling proportion above 90% of the operating fluid. Then, regarding the internal volume of the heating pipes and the operational fluid density at ambient temperature, by the continuous discharge of the R134a gas out of the pipes and simultaneous weighing of the whole apparatus with scales, the desired filling ratio is measured. Thermodynamics properties in experiment situation are statistically shown in Table 1.
Parameters | Unit | R134 |
Viscosity liquid | cp | 0.20 |
Boiling Point @ 1 atm | C | -26.1 |
Liquid density @ 25 C | kg/m3 | 1206 |
Vapor density @ Boiling point | kg/m3 | 5.25 |
Specific heat liquid @ 25 C | kJ/kgK | 1.44 |
After completing and running of the laboratory system, the pressure drop was measured in two various situations. One using a tube equipped by pulse heating pipes (L1) and the other utilizing fin heating pipes (L2), provided that the temperature of the outlet gas is 50 ℃ and the pressure drop measurement is carried out through two Gauge-like barometers at the end of both tubes. Previous studies showed that the overall heat transfer coefficient in a tube using a pulse heating pipe is far better than that of using fins [25]. Therefore, the surface of the exchanger utilized to supply the same temperature in the tube with a pulse heating pipe is expected to be lower, in fact, the tube length is longer, and the surface should be more extensive. For this purpose, through the carried out experiments up to 30 minutes, the axial fans are switched off, and after 30 minutes the fans are switched on (the inverter frequency is set to 10 Hz). It is observed that the performance of both the heating pipe and fin-equipped tubes has improved. Ultimately, after 30 minutes, the condition is balanced. The purpose of this section is to experimentally select the specified length in the exchanger to obtain the same output temperature in both tubes. The results of this test are brought in Figure 2.
Test results show that the temperature within a meter of a tube equipped with heating pulse pipe is 50 ℃, which at the same temperature conditions is 1.5 m long for the tube equipped with fins. The schematics of the experimental system are being shown in Figures 3-5.
The NTU method, using to calculate the heat transfer rate in heat exchangers. This method is used when the temperature not defined in all streams. NTU is a dimensionless parameter ratio that calculated Eqs 1 and 2.
NTU=UtAtCmin | (1) |
Cmin=(˙mcp)min | (2) |
According to Eq 1, total heat transfer area in both tubes in our investigation can be calculated and determine for setup system.
As previously mentioned, the study performed in the laboratory system is following the thermodynamic and operating conditions of one of the pressure boosting stations in Iran. The operating considerations of the station, as well as the design conditions of the air-cooling exchanger which have been the basis of boundary conditions selection in this study, are listed through Tables 2 and 3.
Parameter | Input | Output |
Natural gas temperature (℃) | 86.2 | 50 |
Inserted gas temperature by the fan (℃) | 50 | 55 |
Natural gas flow rate (kg/hr) | 631336 | 631336 |
Inserted gas flow rate (kg/hr) | 4574556 | 4574556 |
Natural gas pressure (kPa) | 6823 | 6623 |
*Gas density in the standard condition is assumed 53.23 kg/m3 in the input. |
Parameter | Unit | Value |
Heat transfer rate | kW | 14300 |
Heat transfer area | m2 | 52011 |
Electro fans number | - | 24 |
Fan power consumption | kW | 37 |
After conducting laboratory tests regarding different inlet gas flow rates to the tube, the results show that the outlet pressure of the tube equipped with a pulse heating pipe is much higher due to the shorter gas passage through the tube. The test results in 4 different gas flow rates, from the highest flow (v1) to the lowest one (v4) inside the tube is shown in Figure 6.
The results pertinent to the measurements in test system prove that in all four modes of inlet fluid velocity to the tube, the L1 tube equipped with a pulse heating pipe endures a higher gas pressure, which was also true in the real conditions of the gas pressure boosting station. Figure 7 shows the improvement in pressure drop (%).
Regarding the laboratory scale, it is not possible to provide the inlet pressure to the exchanger at the gas pressure boost station, which is the output of the gas compressor. For this purpose and considering the linear relationship between velocity and pressure, the percentage of improvement impact in two tubes is used for simulation.
The primary purpose of this study is to reduce the pressure drop triggered in the heat exchanger and to increase the energy performance of the gas pressure boosting station. Since the energy performance index at a pressure boosting station is defined as the ratio of total energy consumed to the overall increase in pressure, the reduction of the energy performance index per a constant pressure rate rise at the gas pressure boosting station requires the decline of the electrical energy or gas consumption. As perceived in this study, the heating pipe is widely utilized as it reduces the surface area of the exchanger and consequently uses a shorter tube to cool the gas to the desired extent, causing the gas to travel through a shorter path in the exchanger. On the other hand, lowering the pressure drop in the case study station will result in entering natural gas to the next station with higher pressure, thus reducing fuel consumption in the turbine. To evaluate the gas-saving capability, the pressure boosting station studied at the next station was simulated in Aspen Hysys software. Then, the inlet pressure to the station was calculated in two different scenarios which are shown schematically in Figure 8.
In the above simulation, the station inlet gas flow (No. 1) with 4903 kPa pressure and 25 ℃ temperature is initially divided into three parts. These three flows include by-pass flow (No. 2), gas flow to boost gas pressure (No. 3), and gas flow to fuel turbine compressors. The exhausted gas from the turbo-compressors flows to the air coolers to lower the temperature, and at the air-cooling exchangers, the gas temperature is reduced to 50 ℃.
After the simulation process in ASPEN-HYSYS, some parameters such as natural gas suction pressure and fuel gas selected to validate the simulation. So, average daily operation data and simulation results in 30 days compared and uncertainty calculation in Figures 9 and 10 show 0.02% and 0.09% error in pressure and temperature suction, respectively. Deviation means that simulation results are acceptable.
The simulation results demonstrate that assuming constant pressure at the gas compressor outlet, the difference in air cooler pressure drop at the previous station will result in lower gas turbine consumption, which this pressure increase at V1 condition (maximum gas flow rate) is about 100 kPa. Figure 11 shows the effect of increasing the inlet pressure to the pressure boosting station at different intervals on a gas turbine.
It should be noted that the results of Figure 11 are calculated for one gas turbine unit. To this end, to calculate the total reduction in turbine fuel consumption considering the layout of the sampling station and the use of 2 turbo-compressors continuously throughout the year, fuel consumption is estimated to be annual as 1.115 MMM3.
The energy performance index, in each natural gas boosting station, includes thermal, electrical and total energy performance that calculated with Eqs 3 to 5.
Total Energy Performance Index= Tetal Energy consumption (kJ) Increased pressure (ΔP) | (3) |
Thermal Energy Perfarmance Index =Fuel Consumption (k)Increased pressure (ΔP) | (4) |
Electrical Energy Performance Index=Electrical Energy Consumptton (kJ)Lncreased pressure (ΔP) | (5) |
The total energy consumption at the gas pressure boosting station divided by the increased pressure indicates the station's energy performance. Also, thermal energy includes fuel gas consumption in the gas turbine, and Electrical energy performance is all electrical consumption related to increased pressure that significant energy users are electro motors in air coolers.
Accordingly, the use of tubes equipped with heating pipes will improve the energy performance index, as illustrated in Figures 12-14.
In the calculations, the thermal value of the gas is considered 45000 kJ/m3 and also the results of the operating conditions survey pertinent to the subject station indicate that amongst the 24 air cooler fans, on average half of them are permanently used during the year. Also, a significant portion of the power consumption at each power-boosting station depends on the air more cooling electro fans and therefore has a dramatic impact on the electrical energy performance index of the station.
Figure 15 shows the results of pressure drop reduction under different conditions of this study.
The calculated pressure drop in the tubes equipped with the heating pipes of the current study shows that in the hot section, 53 kPa is dropped (for natural gas), while in operating conditions for cooling parts, the pressure drop reported in the technical sheet by the air cooling manufacturer has been 200 kPa. In other words, the pressure drop in the heating pipe exchanger design conditions will be approximately four times lower than the current circumstances. In a similar study by Sun et al. (2018), in particular, by combining a series of heating pipes with the use of gravitational force in thermoelectric coolers (TEC), they empirical investigated the valid parameters. The results of this study showed that using the combination mentioned above can improve the cooling capacity by 68% [26]. Another survey by Borlaco et al. in 2018 on the use of a heating pipe system in a building installation proves that the thermal energy performance index has improved by about 30% [27]. Also, researches by Honghai et al. (2007) on the utilization of a type of heating pipe in the building sector have resulted in a 30-50% improvement in air conditioning operation [28].
The goal of this investigation was the experimental implementation of the heat pipe in the finned tube instead of simple finned tube and assets pressure drop and infused in energy performance index in natural gas pressure boosting station. For this purpose, the real case study selected and boundary condition, air cooler size and operation data was recorded. Next, the experimental setup was designed, fabricated and tested in different condition. Also for creating real boundary condition, the gas pressure boosting stations simulated in HYAYS. Comparing results with real the in suction pressure and temperature, show 0.02% and 0.09% error respectively.
One advantage of using tubes equipped with pulse heat pipe is triggering a very low-pressure drop in natural gas. The purpose of a gas pressure boosting station design is to increase the pressure; nevertheless in the current process of a station, as soon as the pressure is enhanced through the turbo-compressor cycle, a percentage of the total pressure increase provided in the cooling section is lost. The results of the analyzing and evaluating the cooling section of the case study gas pressure boosting stations reveal that this section of the station has the potential to improve the energy performance as well as reduce energy consumption and improve its performance. First, outlet temperature in tubes (finned tube, and fin with PHP tube) adjusted at 50 ℃. Experimental results show that the outlet temperature in 1.5 meters of the finned tube and 1-meter fin with PHP tube length is equal. Afterwards, in four-velocity, outlet pressure was calculated and result from show 44.59, 40.40, 36.78 and 23.34% in V1 to V4 improvement in pressure drop. Reducing the pressure drop in air cooler lead to increase suction pressure in the next gas pressure boosting station. Results of simulation show with using PHP tube in an air cooler, energy saving in fuel gas consumption in the next station will be 1, 114, 116 Sm3 annually. Also implemented these type of tube cause to reduce 3, 889, 440 kWh electrical consumption in air coolers. Energy performance calculations for the case study station have revealed the improvement in overall energy performance, thermal performance and electrical energy performance indices up to 3, 2.3 and 79%, respectively. Besides, the development of this design at all pressure boosting stations will also create a very high potential for energy savings.
The authors declare that they have no conflict of interest.
[1] |
N. Balakrishnan, D. Han, Exact inference for a simple step-stress model with competing risks for failure from exponential distribution under Type-II censoring, J. Stat. Plan. Infer., 138 (2008), 4172–4186. https://doi.org/10.1016/j.jspi.2008.03.036 doi: 10.1016/j.jspi.2008.03.036
![]() |
[2] |
N. Balakrishnan, D. Han, Optimal step-stress testing for progressively Type-I censored data from exponential distribution, J. Stat. Plan. Infer., 139 (2009), 1782–1798. https://doi.org/10.1016/j.jspi.2008.05.030 doi: 10.1016/j.jspi.2008.05.030
![]() |
[3] |
F. Haghighi, Optimal design of accelerated life tests for an extension of the exponential distribution, Reliab. Eng. Syst. Safe., 131 (2014), 251–256. https://doi.org/10.1016/j.ress.2014.04.017 doi: 10.1016/j.ress.2014.04.017
![]() |
[4] |
M. W. Lu, R. J. Rudy, Step-stress accelerated test, Int. J. Mater. Prod. Tech., 17 (2002), 425–434. https://doi.org/10.1504/ijmpt.2002.005468 doi: 10.1504/ijmpt.2002.005468
![]() |
[5] |
E. O. McSorley, J. C. Lu, C. S. Li, Performance of parameter-estimates in step-stress accelerated life-tests with various sample-sizes, IEEE Trans. Reliab., 51 (2002), 271–277. https://doi.org/10.1109/tr.2002.802888 doi: 10.1109/tr.2002.802888
![]() |
[6] |
Y. Komori, Properties of the Weibull cumulative exposure model, J. Appl. Stat., 33 (2006), 17–34. https://doi.org/10.1080/02664760500389475 doi: 10.1080/02664760500389475
![]() |
[7] |
W. Chung, D. S. Bai, Optimal designs of simple step-stress accelerated life tests for lognormal lifetime distributions, Int. J. Reliab. Quality Safety Eng., 5 (1998), 315–336. https://doi.org/10.1142/s0218539398000285 doi: 10.1142/s0218539398000285
![]() |
[8] | M. A. H. Ebrahem, A. Q. Al-Masri, Optimum simple step-stress plan for log-logistic cumulative exposure model, Metron-Int. J. Stat., 65 (2007), 23–34. |
[9] | S. O. Bleed, H. M. A. Hasan, Estimating and planning step stress accelerated life test for generalized Logistic distribution under type-I censoring, Int. J. Appl. Math. Stat. Sci., 2 (2013), 1–16. |
[10] |
S.Saxena, S. Zarrin, M. Kamal, A. Ul-Islam, Optimum step stress accelerated life testing for Rayleigh distribution, Int. J. Stat. Appl., 2 (2012), 120–125. https://doi.org/10.5923/j.statistics.20120206.05 doi: 10.5923/j.statistics.20120206.05
![]() |
[11] |
K. Ahmadi, M. Rezaei, F. Yousefzadeh, , Estimation for the generalized half-normal distribution based on progressive type-II censoring, J. Stat. Comput. Sim., 85 (2015), 1128–1150. https://doi.org/10.1080/00949655.2013.867494 doi: 10.1080/00949655.2013.867494
![]() |
[12] |
S. J. Wu, Y. P. Lin, S. T. Chen, Optimal step-stress test under type I progressive group-censoring with random removals, J. Stat. Plan. Infer., 138 (2008), 817–826. https://doi.org/10.1016/j.jspi.2007.02.004 doi: 10.1016/j.jspi.2007.02.004
![]() |
[13] |
N. Balakrishnan, L. Zhang, Q. Xie, Inference for a simple step-stress model with Type-I censoring and lognormally distributed lifetimes, Commun. Stat.–Theor. Methods, 38 (2009), 1690–1709. https://doi.org/10.1080/03610920902866966 doi: 10.1080/03610920902866966
![]() |
[14] |
C. T. Lin, N. Balakrishnan, S. J. Wu, planning life tests based on progressively type-I grouped censored data from the Weibull distribution, Commun. Stat.–Simul. Comput., 40 (2011), 574–595. https://doi.org/10.1080/03610918.2010.549278 doi: 10.1080/03610918.2010.549278
![]() |
[15] | K. U. S. Coşkun, Y. Akdogan, S. J. Wu, Planning life tests for burr XII distributed products under progressive group-censoring with cost considerations, Gazi Univer. J. Sci., 25 (2012), 425–434. |
[16] |
C. Kuş, Y. Akdoğan, S. J. Wu, Optimal progressive group censoring scheme under cost considerations for Pareto distribution, J. Appl. Stat., 40 (2013), 2437–2450. https://doi.org/10.1080/02664763.2013.818107 doi: 10.1080/02664763.2013.818107
![]() |
[17] |
A. S. Hassan, S. M. Assar, A. Shelbaia, Multiple-step stress accelerated life for Weibull Poisson distribution with type I censoring, Int. J. Basic Appl. Sci., 3 (2014), 180. https://doi.org/10.14419/ijbas.v3i3.2533 doi: 10.14419/ijbas.v3i3.2533
![]() |
[18] |
A. A. Ismail, Corrigendum to "Estimating the parameters of Weibull distribution and the acceleration factor from hybrid partially accelerated life test"[Appl. Math. Modell. 36 (2012) 2920–2925], Appl. Math. Model., 39 (2015), 2743. https://doi.org/10.1016/j.apm.2015.07.008 doi: 10.1016/j.apm.2015.07.008
![]() |
[19] |
S. Budhiraja, B. Pradhan, Computing optimum design parameters of a progressive type I interval censored life test from a cost model, Appl. Stoch. Models Bus. Ind., 35 (2017), 494–506. https://doi.org/10.1002/asmb.2251 doi: 10.1002/asmb.2251
![]() |
[20] |
S. Roy, B. Pradhan, Bayesian C-optimal life testing plans under progressive type-I interval censoring scheme, Appl. Math. Model., 70 (2019), 299–314. https://doi.org/10.1016/j.apm.2019.01.023 doi: 10.1016/j.apm.2019.01.023
![]() |
[21] |
J. Wang, Data analysis of step-stress accelerated life test with random group effects under Weibull distribution, Math. Probl. Eng., 2020 (2020), 1–11. https://doi.org/10.1155/2020/4898123 doi: 10.1155/2020/4898123
![]() |
[22] |
R. M. EL-Sagheer, M. A. Khder, Estimation in K-stage step-stress partially accelerated life tests for generalized Pareto distribution with progressive type-I censoring, Appl. Math. Inf. Sci., 15 (2021), 299–305. https://doi.org/10.18576/amis/150307 doi: 10.18576/amis/150307
![]() |
[23] | M. Kamal, S. A. Siddiqui, A. Rahman, H. Alsuhabi, I. Alkhairy, T. S. Barry, Parameter estimation in step stress partially accelerated life testing under different types of censored data, Comput. Intel. Neurosc., 2022 (2022). https://doi.org/10.1155/2022/3491732 |
[24] | L. Zhuang, A. Xu, B. Wang, Y. Xue, S. Zhange, Data analysis of progressive-stress accelerated life tests with group effects, Qual. Technol. Quant. Manage., 20 (2023). https://doi.org/10.1080/16843703.2022.2147690 |
[25] | R. Alotaibi, A. A. Mutairi, E. M. Almetwally, C. Park, H. Rezk, Optimal design for a bivariate step-stress accelerated life test with alpha power exponential distribution based on type-I progressive censored samples, Symmetry, 14 (2022). https://doi.org/10.3390/sym14040830 |
[26] |
X. Bai, Y. Shi, H. K. T. Ng, Statistical inference of Type-I progressively censored step-stress accelerated life test with dependent competing risks, Commun. Stat.-Theor. Methods, 10 (2022), 3077–3103. https://doi.org/10.1080/03610926.2020.1788081 doi: 10.1080/03610926.2020.1788081
![]() |
[27] |
A. M. Almarashi, Inferences of generalized inverted exponential distribution based on partially constant-stress accelerated life testing under progressive Type-II censoring, Alexandria Eng. J., 63 (2023), 223–232. https://doi.org/10.1016/j.aej.2022.07.063 doi: 10.1016/j.aej.2022.07.063
![]() |
[28] | M. Nassar, A. Elshahhat, statistical analysis of inverse Weibull constant-stress partially accelerated life tests with adaptive progressively type I censored data, Mathematics, 11 (2023). https://doi.org/10.3390/math11020370 |
[29] |
I. Alam, A. Haq, L. K. Sharma, S. Sharma, Ritika, Warranty costs analysis under accelerated life test for power Ishita distribution with type-I censored data, Int. J. Qual. Reliab. Manage., 40 (2023), 1983–1998. https://doi.org/10.1108/IJQRM-08-2022-0251 doi: 10.1108/IJQRM-08-2022-0251
![]() |
[30] | A. A. Bhat, S. P. Ahmad, A new generalization of Rayleigh distribution: Properties and applications, Pak. J. Statist., 36 (2020), 225–250. |
[31] |
K. Ateeq, T. B. Qasim, A. R. Alvi, An extension of Rayleigh distribution and applications, Cogent Math. Stat., 6 (2019), 1622191. https://doi.org/10.1080/25742558.2019.1622191 doi: 10.1080/25742558.2019.1622191
![]() |
[32] |
D. Kundu, M. Z. Raqab, Generalized Rayleigh distribution: different methods of estimations, Comput. Stat. Data Anal., 49 (2005), 187–200. https://doi.org/10.1016/j.csda.2004.05.008 doi: 10.1016/j.csda.2004.05.008
![]() |
[33] | A. H. Tolba, T. A. Abushal, D. A. Ramadan, Statistical inference with joint progressive censoring for two populations using power Rayleigh lifetime distribution, Sci. Rep., 13 (2023), 3832. |
[34] |
H. S. Migdadi, N. M. Al-Olaimat, M. Mohiuddin, O. Meqdadi, , Statistical inference for the Power Rayleigh distribution based on adaptive progressive Type-II censored data, AIMS Math., 8 (2023), 22553–22576. http://dx.doi.org/10.3934/math.20231149 doi: 10.3934/math.20231149
![]() |
[35] |
W. Nelson, Accelerated life testing-step-stress models and data analyses, IEEE Trans. Reliab., 29 (1980), 103–108. https://doi.org/10.1109/tr.1980.5220742 doi: 10.1109/tr.1980.5220742
![]() |
[36] |
S. J. Wu, Y. P. Lin, Y. J. Chen, Planning step-stress life test with progressively type I group-censored exponential data, Stat. Neerl., 60 (2006), 46–56. https://doi.org/10.1111/j.1467-9574.2006.00309.x doi: 10.1111/j.1467-9574.2006.00309.x
![]() |
[37] | H. M. Aly, Planning step stress accelerated life test for log logistic distribution under progressive type I group censoring, in Proceedings of the 20th Annual Conference on Statistics and Modeling in Human and Social Science, Cairo University, (2008), 107–125. |
[38] | J. F. Lawless, Statistical models and methods for lifetime data, John Wiley & Sons, 2003. |
[39] |
P. Hall, Theoretical comparison of bootstrap confidence intervals, Ann. Stat., 16 (1988), 927–935. https://doi.org/10.1214/aos/1176350933 doi: 10.1214/aos/1176350933
![]() |
[40] | B. Efron, R. J. Tibshirani, An introduction to the bootstrap, CRC press, 1994. |
[41] |
E. Gouno, A. Sen, N. Balakrishnan, Optimal step-stress test under progressive Type-I censoring, IEEE Trans. Reliab., 53 (2004), 388–393. https://doi.org/10.1109/tr.2004.833320 doi: 10.1109/tr.2004.833320
![]() |
[42] |
R. Al-Aqtash, C. Lee, F. Famoye, Gumbel-Weibull distribution: Properties and applications, J. Modern Appl. Stat. Methods, 13 (2014), 201–255. http://dx.doi.org/10.22237/jmasm/1414815000 doi: 10.22237/jmasm/1414815000
![]() |
[43] |
H. Alkasasbeh, F. M. Al Faqih, A. S. Shoul, Computational Simulation of Magneto Convection Flow of Williamson Hybrid Nanofluid with Thermal Radiation Effect, CFD Letters, 15 (2023), 92–105. https://doi.org/10.37934/cfdl.15.4.92105 doi: 10.37934/cfdl.15.4.92105
![]() |
1. | Fazri Amir, Hafiz Muhammad, Nasruddin A. Abdullah, Samsul Rizal, Razali Thaib, Hamdani Umar, Performance analysis of heat recovery in Heat Pipe Heat Exchanger on room air conditioning systems, 2023, 11, 2333-8334, 612, 10.3934/energy.2023031 |
Parameters | Unit | R134 |
Viscosity liquid | cp | 0.20 |
Boiling Point @ 1 atm | C | -26.1 |
Liquid density @ 25 C | kg/m3 | 1206 |
Vapor density @ Boiling point | kg/m3 | 5.25 |
Specific heat liquid @ 25 C | kJ/kgK | 1.44 |
Parameter | Input | Output |
Natural gas temperature (℃) | 86.2 | 50 |
Inserted gas temperature by the fan (℃) | 50 | 55 |
Natural gas flow rate (kg/hr) | 631336 | 631336 |
Inserted gas flow rate (kg/hr) | 4574556 | 4574556 |
Natural gas pressure (kPa) | 6823 | 6623 |
*Gas density in the standard condition is assumed 53.23 kg/m3 in the input. |
Parameter | Unit | Value |
Heat transfer rate | kW | 14300 |
Heat transfer area | m2 | 52011 |
Electro fans number | - | 24 |
Fan power consumption | kW | 37 |
Parameters | Unit | R134 |
Viscosity liquid | cp | 0.20 |
Boiling Point @ 1 atm | C | -26.1 |
Liquid density @ 25 C | kg/m3 | 1206 |
Vapor density @ Boiling point | kg/m3 | 5.25 |
Specific heat liquid @ 25 C | kJ/kgK | 1.44 |
Parameter | Input | Output |
Natural gas temperature (℃) | 86.2 | 50 |
Inserted gas temperature by the fan (℃) | 50 | 55 |
Natural gas flow rate (kg/hr) | 631336 | 631336 |
Inserted gas flow rate (kg/hr) | 4574556 | 4574556 |
Natural gas pressure (kPa) | 6823 | 6623 |
*Gas density in the standard condition is assumed 53.23 kg/m3 in the input. |
Parameter | Unit | Value |
Heat transfer rate | kW | 14300 |
Heat transfer area | m2 | 52011 |
Electro fans number | - | 24 |
Fan power consumption | kW | 37 |