Sensitivity of hemodynamics in a patient specific cerebral aneurysm to vascular geometry and blood rheology

  • Received: 01 March 2010 Accepted: 29 June 2018 Published: 01 April 2011
  • MSC : Primary: 76A05, 76Z05.

  • Newtonian and generalized Newtonian mathematical models for blood flow are compared in two different reconstructions of an anatomically realistic geometry of a saccular aneurysm, obtained from rotational CTA and differing to within image resolution. The sensitivity of the flow field is sought with respect to geometry reconstruction procedure and mathematical model choice in numerical simulations.
       Taking as example a patient specific intracranial aneurysm located on an outer bend under steady state simulations, it is found that the sensitivity to geometry variability is greater, but comparable, to the one of the rheological model. These sensitivities are not quantifiable a priori. The flow field exhibits a wide range of shear stresses and slow recirculation regions that emphasize the need for careful choice of constitutive models for the blood. On the other hand, the complex geometrical shape of the vessels is found to be sensitive to small scale perturbations within medical imaging resolution.
       The sensitivity to mathematical modeling and geometry definition are important when performing numerical simulations from in vivo data, and should be taken into account when discussing patient specific studies since differences in wall shear stress range from 3% to 18%.

    Citation: Alberto M. Gambaruto, João Janela, Alexandra Moura, Adélia Sequeira. Sensitivity of hemodynamics in a patient specific cerebral aneurysm to vascular geometry and blood rheology[J]. Mathematical Biosciences and Engineering, 2011, 8(2): 409-423. doi: 10.3934/mbe.2011.8.409

    Related Papers:

  • Newtonian and generalized Newtonian mathematical models for blood flow are compared in two different reconstructions of an anatomically realistic geometry of a saccular aneurysm, obtained from rotational CTA and differing to within image resolution. The sensitivity of the flow field is sought with respect to geometry reconstruction procedure and mathematical model choice in numerical simulations.
       Taking as example a patient specific intracranial aneurysm located on an outer bend under steady state simulations, it is found that the sensitivity to geometry variability is greater, but comparable, to the one of the rheological model. These sensitivities are not quantifiable a priori. The flow field exhibits a wide range of shear stresses and slow recirculation regions that emphasize the need for careful choice of constitutive models for the blood. On the other hand, the complex geometrical shape of the vessels is found to be sensitive to small scale perturbations within medical imaging resolution.
       The sensitivity to mathematical modeling and geometry definition are important when performing numerical simulations from in vivo data, and should be taken into account when discussing patient specific studies since differences in wall shear stress range from 3% to 18%.


    加载中
  • Reader Comments
  • © 2011 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Metrics

Article views(2294) PDF downloads(571) Cited by(54)

Article outline

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return

Catalog