Research article

Degradation of poly aromatic fractions of crude oil and detection of catabolic genes in hydrocarbon-degrading bacteria isolated from Agbabu bitumen sediments in Ondo State

  • Pollution due to release of Poly aromatic hydrocarbons (PAHs) are a major environmental issue especially in oil producing communities. This study investigates the polyaromatic hydrocarbon degradation potentials of some bacteria: Campylobacter hominis, Bacillus cereus, Dyadobacter koreensis, Pseudomonas aeruginosa and Micrococcus luteus isolated from Agbabu bitumen sediments in Ondo State. The isolates were used singly and in consortium for the degradation of Bonny light crude oil. Concentrations of residual aromatic hydrocarbons in crude oil degraded by these isolates were determined by Gas chromatography/Mass Spectroscopy with flame ionization detector (FID). Detection of catabolic genes (nahH, CatA and AlkB) in the isolates was determined by PCR amplification of their specific primers. The GC-MS analyses showed degradation of poly aromatic hydrocarbons (PAHs) by these isolates. The consortium exhibited the highest PAH reduction (73%) while C. hominis had the least PAH reduction (56%). Dyadobacter koreensis, P. aeruginosa, Micrococcus luteus and B. cereus, displayed 66%, 60%, 59% and 58% PAH reduction respectively. The catabolic gene nahH gene was present in B. cereus, D. koreensis, P. aeruginosa and M. luteus, alkB gene was present in B. cereus, C. hominis, and D. koreensis while CatA was not detected in any of the isolates. The findings of this study affirmed the hydrocarbon-degrading abilities and presence of catabolic genes in these bacteria, these make them potential tools in oil prospecting and cleaning up of hydrocarbon contaminated sites.

    Citation: Temitayo O. Olowomofe, J. O. Oluyege, B.I. Aderiye, O. A. Oluwole. Degradation of poly aromatic fractions of crude oil and detection of catabolic genes in hydrocarbon-degrading bacteria isolated from Agbabu bitumen sediments in Ondo State[J]. AIMS Microbiology, 2019, 5(4): 308-323. doi: 10.3934/microbiol.2019.4.308

    Related Papers:

    [1] Mohamed G Moh Almihat . An overview of AC and DC microgrid energy management systems. AIMS Energy, 2023, 11(6): 1031-1069. doi: 10.3934/energy.2023049
    [2] Z. Ismaila, O. A. Falode, C. J. Diji, R. A. Kazeem, O. M. Ikumapayi, M. O. Petinrin, A. A. Awonusi, S. O. Adejuwon, T-C. Jen, S. A. Akinlabi, E. T. Akinlabi . Evaluation of a hybrid solar power system as a potential replacement for urban residential and medical economic activity areas in southern Nigeria. AIMS Energy, 2023, 11(2): 319-336. doi: 10.3934/energy.2023017
    [3] Syed Sabir Hussain Rizvi, Krishna Teerth Chaturvedi, Mohan Lal Kolhe . A review on peak shaving techniques for smart grids. AIMS Energy, 2023, 11(4): 723-752. doi: 10.3934/energy.2023036
    [4] Virendra Sharma, Lata Gidwani . Optimistic use of battery energy storage system to mitigate grid disturbances in the hybrid power system. AIMS Energy, 2019, 7(6): 688-709. doi: 10.3934/energy.2019.6.688
    [5] Sulabh Sachan . Integration of electric vehicles with optimum sized storage for grid connected photo-voltaic system. AIMS Energy, 2017, 5(6): 997-1012. doi: 10.3934/energy.2017.6.997
    [6] Rashid Al Badwawi, Mohammad Abusara, Tapas Mallick . Speed control of synchronous machine by changing duty cycle of DC/DC buck converter. AIMS Energy, 2015, 3(4): 728-739. doi: 10.3934/energy.2015.4.728
    [7] Khuthadzo Kgopana, Olawale Popoola . Improved utilization of hybrid energy for low-income houses based on energy consumption pattern. AIMS Energy, 2023, 11(1): 79-109. doi: 10.3934/energy.2023005
    [8] Aaron St. Leger . Demand response impacts on off-grid hybrid photovoltaic-diesel generator microgrids. AIMS Energy, 2015, 3(3): 360-376. doi: 10.3934/energy.2015.3.360
    [9] Tilahun Nigussie, Wondwossen Bogale, Feyisa Bekele, Edessa Dribssa . Feasibility study for power generation using off- grid energy system from micro hydro-PV-diesel generator-battery for rural area of Ethiopia: The case of Melkey Hera village, Western Ethiopia. AIMS Energy, 2017, 5(4): 667-690. doi: 10.3934/energy.2017.4.667
    [10] Mohamed Elweddad, Muhammet Güneşer, Ziyodulla Yusupov . Designing an energy management system for household consumptions with an off-grid hybrid power system. AIMS Energy, 2022, 10(4): 801-830. doi: 10.3934/energy.2022036
  • Pollution due to release of Poly aromatic hydrocarbons (PAHs) are a major environmental issue especially in oil producing communities. This study investigates the polyaromatic hydrocarbon degradation potentials of some bacteria: Campylobacter hominis, Bacillus cereus, Dyadobacter koreensis, Pseudomonas aeruginosa and Micrococcus luteus isolated from Agbabu bitumen sediments in Ondo State. The isolates were used singly and in consortium for the degradation of Bonny light crude oil. Concentrations of residual aromatic hydrocarbons in crude oil degraded by these isolates were determined by Gas chromatography/Mass Spectroscopy with flame ionization detector (FID). Detection of catabolic genes (nahH, CatA and AlkB) in the isolates was determined by PCR amplification of their specific primers. The GC-MS analyses showed degradation of poly aromatic hydrocarbons (PAHs) by these isolates. The consortium exhibited the highest PAH reduction (73%) while C. hominis had the least PAH reduction (56%). Dyadobacter koreensis, P. aeruginosa, Micrococcus luteus and B. cereus, displayed 66%, 60%, 59% and 58% PAH reduction respectively. The catabolic gene nahH gene was present in B. cereus, D. koreensis, P. aeruginosa and M. luteus, alkB gene was present in B. cereus, C. hominis, and D. koreensis while CatA was not detected in any of the isolates. The findings of this study affirmed the hydrocarbon-degrading abilities and presence of catabolic genes in these bacteria, these make them potential tools in oil prospecting and cleaning up of hydrocarbon contaminated sites.


    Nearly one third of the world population is not electrified due to lack of generation, geographical, environmental and logistic concerns. Extending power lines from centralized sources to rural areas where electrification is embryonic is often not yet economical, and so, decentralized and off-grid power sources, such as standalone PV systems, are a promising alternative [1].

    The intermittent and stochastic nature of PV production could be addressed by having an appropriate energy storage. When grid connected, if there is an imbalance of demand and the PV generation, the utility grid ensures an uninterruptible power supply to the load [2,3,4]. But unlike in grid-connected case, in standalone PV systems, any mismatch between the demand and PV generation should be compensated by the energy storage (ES) [5,6]. Even with the grid connected case, there might be situations where grid is unavailable for supplying loads, (e.g., grid outage, islanding condition etc.) leading the PV system to be changed its working mode from grid connected to standalone [7]. Among many types of ES elements, chemical batteries are employed as mainstream long term ES solution for different kind of energy systems, particularly Lead Acid (LA) batteries with well proven technology due to its better electrical performance and relatively lower cost. Despite economical and electrical merits associated with LA batteries, the battery itself is not be an appropriate ES element in PV systems as the life cycle of LA battery is relatively short which only last for hundreds of charge-discharge cycles [8]. Due to the stochastic nature of PV generation, the deterioration of the LA battery could be worse as it fails to ensure charging and discharging security due to deep discharged, overcharging, high charging rate and fluctuating power exchange [8,9,10]. In order to address fast dynamics and sudden fluctuations in power intensive load (e.g., EV load, emergency power management), a super-capacitor(SC) should be embedded in the energy storage as it can absorb and deliver power fluctuations at much higher rates compared to batteries and also it can be considered that charging and discharging cycles of a SC is almost unlimited [5,8,11]. Therefore, it is recommended to use a battery with a SC as a hybrid ES (HES) in renewable energy applications to address its intermittency while ensuring long life cycle of the battery array.

    A typical DC coupled active topology of a HES found in recent literature is depicted in Figure 1 where the battery array and SC are connected to a common DC bus [12,13,14,15,16]. A passive HES topology described in [17] can also share the load current between the battery and the SC while keeping the terminal voltage constant due to the parallel connection. In this topology, for fast dynamics in the load demand, the SC responses rapidly to satisfy the sudden changes in the demand which in consequence leads the battery current to gradually increase or decrease. However, in this topology, the individual power share can not be controlled independently unlike in the active topology illustrated in Figure 1, as the current distribution between the battery and SC solely depend on the internal electrical properties such as resistance, capacitance etc [13].

    Figure 1.  HES Topologies.

    The power share among ES elements should be determined using appropriate techniques considering the characteristics of ESs. Independent control of the power flow of each energy storage element in a HES is useful, but to counter balance the system reliability and availability, secondary control layer would be necessary on top of the calculated power references. Reference [18] has employed fuzzy control to further modify and smooth the calculated power references for a HES but it has not given a significant attention to control strategies related to the voltage source inverter (VSI) in the SPVS application. Although considerable research efforts have been devoted to primary control of the power conditioning devices connected to the HES in a SPVS, less attention has been paid on the secondary control with energy management ensuring an uninterruptible power supply to the power intensive load with transients. Therefore, in this work, a hierarchical control approach as a finite state machine (FSM) is proposed and analyzed for the DC coupled HES in active topology. The initial power references for each ES element is calculated using power transient filtering. The control strategies are analyzed for both the DC-DC and DC-AC stages to ensure an uninterruptible power supply to the AC load while maintaining system reliability, availability and dispatching security.

    In this article, Section 2 presents the configuration of the HES topology and the components. Section 3 describes the control strategies proposed as a FSM while the Section 4 is presenting the PWM switching control with classical PID control. The simulation results are presented and discussed in Section 5. The performance of the proposed control strategies are concluded in Section 6.

    In the presented work, ES elements are interfaced in DC coupled active topology to supply the power intensive load as depicted in Figure 2. Power shares of ES elements are determined using power transient filtering techniques. The energy sources are connected with the power intensive load through power conditioning devices with the control system as illustrated in Figure 2. The control system is developed in hierarchical fashion with dedicated control tasks at different stages to supply the required demand while ensuring charging and discharging security of the HES.

    Figure 2.  DC Coupled Architecture of the HES.

    The charging and discharging characteristics of the selected LA battery model are expressed in (2.1) and (2.2) respectively [19]. The sizing of the battery array is done based on the work presented in [9,20] with the power rating of $ 8 \quad kW $. The DC bus to which the battery is connected through a bi-directional DC-DC converter is kept at $ 60 \quad V $. The manufacture specified battery parameters are given in Table 1. According to the selected battery, the battery array consists of $ 7 $ batteries connected in parallel to meet the load demand.

    $ ECharge=E0K×(QQit)×iK×(QQit)×it+L1(Exp(s)sel(s))
    $
    (2.1)
    $ EDischarge=E0K×(Q0.1Q+it)×iK×(QQit)×it+L1(Exp(s)sel(s)×1s)
    $
    (2.2)
    Table 1.  Battery parameters.
    Parameters Data
    Nominal Voltage 48 V
    Rated Capacity 69.4 Ah
    Initial State of Charge 80%
    Fully Charged Voltage 52.3 V
    Nominal Discharge Current 35 A
    Internal Resistance 0.02 $ \Omega $
    Capacity at Nominal Voltage 21.5 Ah

     | Show Table
    DownLoad: CSV

    where,

    $ E_{0} $: Constant voltage $ (V) $

    $ Exp(s) $: Exponential zone dynamics $ (V) $

    $ sel(s) $: Battery mode: $ sel(s) = 1 $ during charging and $ sel(s) = 0 $ during discharging

    $ K $: Polarization constant $ (Ah^{-1}) $ or Polarization resistance $ (\Omega) $

    $ i^{*} $: Low frequency current dynamics $ (A) $

    $ i $: Battery current $ (A) $

    $ it $: Expected capacity $ (Ah) $

    $ Q $: Maximum battery capacity $ (Ah) $

    SC is used to address the sudden power transients in the system rather taking a large portion of the load demand. However, the power rating of the SC should be large enough to address load transients and also SC should be capable of taking a significant share of the demand when the battery array is to be exceeded its power ratings.

    The output voltage of the SC model used in this work is expressed using a Stern equation given in (2.3) [19]. The power ratings of the selected SC is $ 2.5 \quad kW $ and the DC bus to which the SC is connected through a bi-directional DC-DC converter is kept at $ 60 \quad V $. The nominal voltage of the SC is selected as $ 24 \quad V $. The SC model parameters given in Table 2 [21].

    $ Vsc=NsQTdNpNeεε0+2NeNsRTFsinh(QTNpN2eAi8RTεε0)Rscisc
    $
    (2.3)
    Table 2.  Super-capacitor parameters.
    Parameters Data
    Rated Capacitance 96 F
    Equivalent DC series resistance $ 2.1\times10^{-3} \quad \Omega $
    Initial State of Charge 65%
    Rated Voltage 36 V
    Initial Voltage 24 V
    Nuber of series capacitors 2
    Number of parallel capacitors 4

     | Show Table
    DownLoad: CSV

    where,

    $ Q_{T} = \int i_{sc} dt $ : Electric charge $ (C) $

    $ A_{i} $: Inter-facial area between electrode and electrolyte $ (m^{2}) $

    $ F $: Faraday constant $ (V) $

    $ i_{sc} $: Super capacitor current$ (A) $

    $ V_{sc} $: Super capacitor voltage $ (V) $

    $ N_{e} $: Number of layers of electrodes

    $ N_{p}, \quad N_{s} $: Number of parallel and series SCs

    $ R $: Ideal gas constant

    $ T $: Operating temperature $ (K) $

    $ \varepsilon, \quad \varepsilon_{0} $: Permitivity of material and the free space

    The system consists of two bi-directional DC-DC buck-boost converters and one $ 3\phi $ VSI as power conditioning devices. In the HES system, both the bi-directional DC-DC buck-boost converters connected with the LA battery and SC arrays facilitate both charging and discharging modes as they are capable of handling bi-directional regulated power flow. The critical parameters of the DC-DC converters are calculated based on the methodology presented in [10]. As the DC coupled architecture is used in the HES, one VSI is employed with voltage mode control.

    The power dispatching strategies are designed in hierarchical fashion as an event driven system with PID and state-flow control. Hierarchical control approach includes several hierarchical stages and each stage is responsible for doing a control task based on its hierarchical position. Therefore, the control system includes four stages each having their own control task depend on the hierarchical position as illustrated in Figure 3.

    Figure 3.  Hierarchical control structure.

    The whole control task is subdivided into three hierarchical stages as illustrated in Figure 3. The top most working mode control (WMC) layer selects the suitable ES elements based on their availability and accessibility so that it prevents the ES elements from over charging and discharging by taking the prescribed maximum and minimum state of charge (SOC) limits of the battery into account. This layer determines the required power, frequency and voltage set points to meet the load demand. Power shares are determined at the power flow control (PFC) layer based on power transient filtering technique but the determined power references are further modified according to the power ratings and the discharging rates of the ES elements using event driven state-flow control. Based on the reference power signals calculated at the PFC, switching control (SWC) level generates the required PWM signals to converters.

    At this stage, the availability and the accessibility of each ES element for power dispatching are determined based on their SOC. The control layer is designed as an event driven system with state-flow control. The state transition diagram of the WMC layer for the HES system is shown in Figure 4 and the corresponding state transition logic is tabulated in Table 3.

    Table 3.  State transition logic of WMs.
    Transition Logic
    $ T_{11} $ $ SOC_{bat}(t) > SOC_{bat, min} ~~\& \& ~~ SOC_{sc}(t) < SOC_{sc, min} $
    $ T_{12} $ $ SOC_{bat}(t) > SOC_{bat, min}~~ \& \& ~~ SOC_{sc}(t) > SOC_{sc, min} $
    $ T_{13} $ $ SOC_{bat}(t) < SOC_{bat, min} ~~ \& \& ~~ SOC_{sc}(t) < SOC_{sc, min} $
    $ T_{14} $ $ SOC_{bat}(t) < SOC_{bat, min} $

     | Show Table
    DownLoad: CSV
    Figure 4.  State transition diagram of the WMC layer.

    $ h $: Hybrid mode.

    $ b $: Battery only mode

    $ d $: Disconnected mode

    $ SOC_{x, min} $: minimum SOC of the ES element $ x $

    $ SOC_{x}(t) $: current SOC of ES element $ x $

    $ x $: battery-$ bat $, SC-$ sc $

    Power will be delivered to the load only in the 'Hybrid' and 'Battery only' modes. Power shares of each ES element will be determined by using linear filtering technique considering the load increment rate and the power transient frequency.

    The 'Hybrid'($ h $) mode in Figure 4 consists of three states ($ s $) : 'Fully dispatchable'($ f $), 'Limited' ($ l $) and 'Disconnected'($ d $) as illustrated in the state diagram of PFC (Figure 5).

    Figure 5.  State transition diagram of the Hybrid mode in PFC.

    There are only two states ($ s $) : 'Connected'($ c $) and 'Disconnected'($ d $) in the 'Battery Only' mode. The state transition logic of PFC-Hybrid mode is tabulated in Table 4. Therefore, the final power references of the battery and SC for $ f $ and $ l $ states are calculated using (3.1) and (3.2), respectively. When the calculated battery power share using power transient filtering is higher than the maximum allowable capacity of the battery, the system transits to the $ l $ state where the initial power reference will be updated to a predetermined percentage (e.g., 0.8) of the calculated reference as described in (3.1).

    Table 4.  State transition logic of PFC-Hybrid.
    Transition Logic
    $ T_{21} $ $ P_{max, sc}+ P_{max, bat} < P_{L}(t) $
    $ T_{22} $ $ P_{max, sc}+ P_{max, bat} > P_{L}(t) $
    $ T_{23} $ $ P_{bat}(t) > P_{max, bat} \quad \& \& \quad P_{sc}(t) < P_{max, sc} $
    $ T_{24} $ $ P_{bat}(t) < P_{max, bat} \quad \& \& \quad P_{sc}(t) < P_{max, sc} $
    $ T_{25} $ $ P_{sc}(t) > P_{max, sc} $

     | Show Table
    DownLoad: CSV

    $ P_{x, max} $: power rating of the ES element $ x $

    $ P_{x}(t) $: calculated share of ES element $ x $

    $ P_{L}(t) $: current load demand

    (3.1)
    (3.2)

    There are two states($ s $) in the PFC of the 'Battery only' mode :'Connected' ($ c $) and 'Disconnected' ($ d $) where only the battery array takes care of the load demand hence, sudden power fluctuations will not be addressed. The load is supplied as long as $ P_{max, bat} > P_{L}(t) $ only, otherwise the system transits to $ d $. Therefore, the final battery and SC power references for 'Battery only' states are calculated using (3.3) and (3.4), respectively.

    (3.3)
    (3.4)

    However, the calculated final reference values of the battery and SC are further checked for the power ratings of each ES element before sending them to the SC layer where PWM switching signals are generated. Therefore, the final reference values for the battery and SC are obtained using (3.5) and (3.6), respectively.

    (3.5)
    (3.6)

    $ P_{ref, x, j}~~~ $: Power reference of $ x $ element in $ j $ mode $ x $: battery ($ bat $), SC ($ sc $),

    $ P_{x, max}~~~ $: Power rating of $ x $ element $ j $: hybrid ($ hyb $), battery only ($ bo $)

    As illustrated in Figure 6, the attention is given to PWM switching controls of the power conditioning devices in the system. Basically what SWC layer does is generating the appropriate PWM switching signal to DC-DC bidirectional converters and the $ 3\phi $ VSI for delivering the required power demand.

    Figure 6.  PWM switching control (SWC) system.

    Individual power shares of each ES element is controlled using two PID control loops based on the reference values of the current components $ (i_{ref, bat}, i_{ref, sc, }) $ calculated from the corresponding power references $ (P_{ref, bat}, P_{ref, sc, }) $ received from the PFC layer. This classical PID control is described in [10]. To keep the DC link voltage constant, a cascaded voltage control loop is used with the battery array as the SC is dedicated for handling sudden power transients while supplying a share of the load demand. The $ 3\phi $ VSI is controlled in grid forming mode using voltage mode control as the load management system is designed for a standalone application as illustrated in Figure 6. All the reference values ($ v_{d, ref}, v_{q, ref} $ and $ f_{ref} $) are obtained from the PFC layer to generate the required AC signal. The block diagram view and the control block diagram of the SWC topology used in the VSI connected with the DC link is shown in Figure 7.

    Figure 7.  The block diagram of the SWC in the VSI.

    There are two main subsystems: (1) Park component derivation subsystem (2) Voltage control subsystem, in the block diagram shown in Figure 7. The Park component derivation subsystem converts the measured line voltage wave-forms $ (v_{abc}) $ at the point of common cupping (PCC) with the AC bus into Park components ($ v_{d}, v_{q}) $ in $ pu $ values with the help of the phase angle $ (\omega t) $. In this SWC topology, voltage controller is used to control the output voltage. Then in the SWC, the direct axis Park component of the reference voltage is set to $ 1 \quad pu $ $ (v_{d, ref} = 1 \quad pu) $ and it generates the required $ v_{d}, v_{q} $ for the PWM generation subsystem.

    The proposed control strategies of the HES are analyzed and the obtained results are presented for three scenarios where fast dynamic, slow dynamic and constant load profiles are considered, respectively. The load demand is properly shared between the battery and SC in the HES. The LA battery array is the main power source which takes the significant portion of the load demand while the SC is taking care of rapid dynamics of the power intensive load.

    Demand management capability of the proposed HES architecture for a load profile with rapid dynamics is evaluated for the load profile illustrated in Figure 8. It can be seen that the large portion of the load demand is taken by the battery. System dispatches the power in 'Hybrid' mode and the power flow is taken place in both 'fully dispatchable' and 'limited' states.

    Figure 8.  Variation of Power Shares of each ES Elements for Scenario Ⅰ.

    When we consider the load variation (Figure 8), rapid dynamics of the load demand can be seen during $ 4^{th} $ second to $ 13^{th} $ second. During the considered simulation time period, the peak demand of $ 8.5 \quad kW $ has been occurred at the $ 9^{th} $ second. Out of this $ 8.5 \quad kW $ demand, $ 23\% $ is taken by the SC array while LA is taking $ 77\% $. From $ 8^{th} $ second to $ 9^{th} $ second, we can see a sudden increment of the load demand with a rate of $ 3.5 \quad kW/s $. During this period SC array has discharged power at a rate of $ 1.95 \quad kW/s $ after being in rest, as the battery has failed to accomplish this sudden load change with alone. During this period the battery response is $ 1.55 \quad kW/s $ which is not sufficient to meet this sudden demand change.

    Similarly, during next two seconds ($ 9^{th} s-11^{th}s $), a sudden demand decrement has been occurred which is even failed to addressed by the LA battery alone. During this time, load demand is decreased at a rate of $ 3.0 \quad kW/s $. SC array has suddenly disappeared at a rate of $ -3.9 \quad kW/s $ while the LA battery keep discharging power at a rate of $ 1.55 \quad kW/s $. At the $ 10^{th} $ second, the share of battery discharge is $ 165\% $ with respect to the load demand but, the excess energy is stored in the SC array at a rate of $ -2.2 \quad kW/s $ during this rapid load change. The same discharging pattern continues till $ 11^{th} $ second resulting battery share of $ 4.9 \quad kW $ and SC share of $ -1.9 \quad kW $ at the $ 11^{th}s $.

    The variation of the SOC, current and the terminal voltage of battery and SC for Scenario Ⅰ are shown in Figure 9 and Figure 10, respectively.

    Figure 9.  Variation of the Current, Voltage and SOC of the Battery for Scenario Ⅰ.
    Figure 10.  Variation of the Current, Voltage and SOC of the SC for Scenario Ⅰ.

    System response for a load variation with slow dynamics is analyzed with the load profile illustrated in Figure 11. Similarly like in Senario Ⅰ, the system dispatches the power in 'Hybrid' mode and the power flow is taken place in both 'fully dispatchable' and 'limited' states. As compared to the load variation in Senario Ⅰ, very slow dynamics appear in the Senario Ⅱ. Due to the rate limiter in the battery power management system, during the first and last few seconds, SC discharges to compensate the load demand and it can be seen that the load demand is almost fulfilled by the LA battery array in its 'fully dispatchable' state.

    Figure 11.  Variation of Power Shares of each ES Elements for Scenario Ⅱ.

    The variation of the SOC, current and the terminal voltage of battery and SC for Scenario Ⅱ are shown in Figure 12 and Figure 13, respectively.

    Figure 12.  Variation of the Current, Voltage and SOC of the Battery for Scenario Ⅱ.
    Figure 13.  Variation of the Current, Voltage and SOC of the SC for Scenario Ⅱ.

    To analyze the performance of proposed power management strategies for 'Battery only' mode, a constant load profile is considered as shown in Figure 14. When the SC array is not available for power dispatching, power transients can not be handled. Therefore, either constant load or a load with very slow dynamics can only be handled in 'Battery only' mode.

    Figure 14.  Variation of Power Shares of each ES Elements for Scenario Ⅲ.

    In Scenario-Ⅰ, it can be seen that the transients of the load profile are filtered and compensated by the SC. The system is working in the $ h $ mode and both $ f $ and $ l $ states. Very slow dynamics are appearing in the load profile analyzed in Scenario-Ⅱ, and so, the load demand is taken by the LA battery array. At the start and the end, SC has taken a power share of the load, as the system has switched to $ l $ state of the $ h $ mode during those periods. To analyze the performance of control strategies proposed in $ b $ mode, the constant load profile is considered in the Scenario-Ⅲ, and it can be seen that, as long as the battery array is available, the constant load profile can be supplied by the system.

    In standalone energy systems as well as in islanding mode of the grid connected PV systems, LA batteries serve as the long term energy storage by taking large portion of the load while sudden changes are being handled by a SC array embedded with the LA battery as a hybrid energy storage. It can be seen that the given HES architecture with the proposed control strategies developed in hierarchical manner effectively address the fast dynamics of the load demand without stressing the LA battery. Power dispatching strategies are developed by using current mode control and voltage mode control adapted at the bi-directional DC-DC converters and the voltage source inverter of the proposed HES with the help of state flow based event driven and PID control systems. Rather using only primary control for the power conditioning devices, it is very effective to implement logical control on top of the primary switching control in hierarchical manner to maintain smooth power supply to the load ensuring healthy operation.

    In this work, the power shares determined by using the power transient filtering technique are further modified by considering the availability and accessibility of each power source to ensure an uninterruptible power supply to the load. It could be concluded that the proposed architecture and the control strategies for a HES connected in DC coupled nature helps not only in increasing more utilization of battery power to meet the rapid varying load demand but also in improving system dynamics and stability in addition to enhance the life expectancy of LA battery.

    This proposed HES system with control strategies can be directly used for fast charging of EV without stressing the electrical grid and also which is best suited for industrial drives as well. The presented power dispatching topology is going to be very useful for emergency power management using HES during disaster relief efforts. In future works, this work will be extended to a PV based DC micro-grid with both dispatching and changing control.

    This work is partially supported by the Norwegian Ministry of Foreign Affairs through the Royal Norwegian Embassy, New Delhi under the framework agreement with TERI (India) and University of Agder (Norway) for the project theme ‘Sustainability and Clean Energy’.

    The authors declare no conflict of interest in this paper.


    Acknowledgments



    We are grateful to Ekiti State government for the funds given to us through the Ekiti State Scholarship Board Scheme to finance the project.

    Conflict of interest



    The authors declare that there is no conflict of interests regarding the publication of this article.

    [1] Oboh BO, Ilori OM, Akinyemi JO, et al. (2006) Hydrocarbon degrading potentials of bacteria isolated from a Nigeria Bitumen (Tarsand) deposit. Nat Sci 4: 51–57.
    [2] Kadafa AA (2012) Environmental impacts of oil exploration and exploitation in the Niger Delta of Nigeria. Global J Sci Front Res Environ Earth Sci 12: 19–28.
    [3] F M E. (2006) Niger Delta natural resource damage assessment and restoration project: Phase 1-Scoping report. Res J Environ Toxicol 10: 29–37.
    [4] Bidoia ED, Montagnolli RN, Lopes PRM (2010) Microbial biodegradation potential of hydrocarbons evaluated by colorimetric technique: a case study, In: Mendez-Vilas A, Current research, technology and education topics in applied microbiology and microbial biotechnology, FORMATEX, Badajoz, Spain, 40–45.
    [5] Mwaura AN, Mbatia BN, Muge EK, et al. (2018) Screening and characterization of hydrocarbonoclastic bacteria isolated from oil-contaminated soils from auto garages. Int J Microbiol Biotechn 3: 11–24. doi: 10.11648/j.ijmb.20180301.13
    [6] Boonchan S, Britz ML, Stanley GA (2000) Degradation and mineralization of high-molecular-weight polycyclic aromatic hydrocarbons by defined fungal-bacterial co-cultures. Appl Environ Microbiol 66: 1007–1019. doi: 10.1128/AEM.66.3.1007-1019.2000
    [7] Mao J, Luo Y, Teng Y, et al. (2012) Bioremediation of polycyclic aromatic hydrocarbon-contaminated soil by a bacterial consortium and associated microbial community changes. Int Biodeterior Biodegrad 70: 141–147. doi: 10.1016/j.ibiod.2012.03.002
    [8] Lam SS, Russell AD, Lee CL, et al. (2012) Production of hydrogen and light hydrocarbons as a potential gaseous fuel from microwave-heated pyrolysis of waste automotive engine oil. Int J Hydrogen Energ 30: 5011–5021.
    [9] Islas-garcia A, Vega-loyo L, Aguilar-lopez R, et al. (2015) Evaluation of hydrocarbons and organochlorine pesticides and their tolerant microorganisms from an agricultural soil to define its bioremediation feasibility. J Environ Sci Health B 50: 99–108. doi: 10.1080/03601234.2015.975605
    [10] Watanabe K (2001) Microorganisms relevant to bioremediation. Curr Opin Biotechnol 12: 231–241. doi: 10.1016/S0958-1669(00)00204-4
    [11] Bushnell LD, Haas HF (1941) The utilization of hydrocarbons by microorganisms. J Bacteriol 41: 653–673.
    [12] Oluwole OA, Oluyege JO, Odeyemi AT, et al. (2017) Growth patterns and degradative potentials of Pseudomonas sp. isolated from waste dumpsite soil in crude oil supplemented soil extract and mineral salts media. J Adv Biolo Biotechnol 12: 1–23.
    [13] Margesin R, Schinner F (2001) Bioremediation (natural attenuation and biostimulation) of diesel-oil-contaminated soil in Alpine glacier sking area. Appl Environ Microbiol 67: 3127–3133. doi: 10.1128/AEM.67.7.3127-3133.2001
    [14] Semple KT, Morriss A, Paton GI (2003) Bioavailability of hydrophobic organic contaminants in soils: fundamental concepts and techniques for analysis. Eur J Soil Sci 54: 809–818. doi: 10.1046/j.1351-0754.2003.0564.x
    [15] Sathishkumar M, Arthur RB, Sang-Ho B, et al. (2008) Biodegradation of crude oil by individual bacterial strains and a mixed bacterial consortium isolated from hydrocarbon contaminated areas. Clean 36: 92–96.
    [16] Obayori OS, Ilori MO, Adebusoye SA, et al. (2009b) Degradation of hydrocarbons and biosurfactant production by Pseudomonas sp. strain LP1. World J Microb Biot 25: 1615–1623.
    [17] Olabemiwo MO, Adediran GO, Adekola FA, et al. (2014) Biodegradation of hydrocarbon compounds in Agbabu natural bitumen. Afr J Biotechnol 13: 1257–1264. doi: 10.5897/AJB2013.12974
    [18] Olowomofe Temitayo O, Oluyege JO, Olawole OA, et al. (2018) Catechol-2,3-dioxygenase and Lipase Activities during Degradation of Crude Oil by Hydrocarbon-degrading Bacteria Isolated from Bitumen-polluted Surface Water in Agbabu, Ondo State. Int J Environ Biorem Biodegrad 6: 18–25.
    [19] Olowomofe TO, Oluyege JO, Sowole DO (2017) Isolation, screening and characterization of hydrocarbon-utilizing bacteria isolated from bitumen-contaminated surface water in Agbabu, Ondo State. J Adv Biol Biotechnol 15: 1–9.
    [20] Orhorhoro E, Effiong E, Abu G (2018) Laboratory-scale bioremediation of crude oil polluted soil using a consortia of rhizobacteria obtained from plants in Gokana-Ogoni, Rivers State. J Adv Microbiol 9: 1–17.
    [21] Minai-Tehrani D, Herfatmanesh A (2007) Biodegradation of aliphatic and aromatic fractions of heavy crude oil-contaminated soil: a pilot study. J Biodegrad Biorem 11: 71–76.
    [22] Baek KH, Yoon BD, Oh HM, et al. (2006) Biodegradation of aliphatic and aromatic hydrocarbons by Nocardia sp. H17–1. Geomicrobiology J 23: 253–259. doi: 10.1080/01490450600760633
    [23] Tancsics A, Szabó I, Baka E, et al. (2008) Investigation of catechol 2,3-dioxygenase and 16S rRNA gene diversity in hypoxic, petroleum hydrocarbon contaminated groundwater. Syst Appl Microbiol 33: 398–406.
    [24] Khan MA, Biswas B, Smith E, et al. (2018) Toxicity assessment of fresh and weathered petroleum hydrocarbons in contaminated soil. Chemosphere 8: 35–42.
    [25] Aurepatipan N, Champreda V, Kanokratana P, et al. (2018) Assessment of bacterial communities and activities of thermotolerant enzymes produced by bacteria indigenous to oil- bearing sandstone cores for potential application in Enhanced Oil Recovery. J Petroleum Sci Eng163: 295–302.
    [26] Ji H, Gong Y, Duan J, et al. (2018) Degradation of petroleum hydrocarbons in seawater by simulated surface level atmospheric ozone: reaction kinetics and effect of oil dispersant. Mar Pollut Bull 135: 427–440. doi: 10.1016/j.marpolbul.2018.07.047
    [27] Gupta G, Kumar V, Pal AK (2016) Biodegradation of polycyclic aromatic hydrocarbons by microbial consortium: a distinctive approach for decontamination of soil. Soil Sediment Contam 25: 597–623. doi: 10.1080/15320383.2016.1190311
    [28] Das K, Mukherjee F (2007) Crude petroleum-oil biodegradation efficiency of Bacillus subtilis and Pseudomonas aeruginosa strains isolated from a petroleum-oil contaminated soil from North-East India. Bioresour Technol 98: 1339–1345. doi: 10.1016/j.biortech.2006.05.032
    [29] Amini S, Zulkify AH, et al. (2011) Molecular identification and characterization of a bacterium that has potential to degrade low concentration of halo alkanoic acid. Res J Microbiol 6: 552–559. doi: 10.3923/jm.2011.552.559
    [30] Olabemiwo OM, Adediran GO, Adekola FA, et al. (2011) Impact of simulated Agbabu bitumen Leachate on haematological and biochemical parameters of wistar albino rat. Res J Environ Toxicol 5: 213–221. doi: 10.3923/rjet.2011.213.221
    [31] International Agency for Research on Cancer (IARC) (2010) Some non-heterocyclic polycyclic aromatic hydrocarbons and some related exposures. Int Agency Res Cancer 92: 45–66.
    [32] Deng D, Li C, Ju Q, et al. (1999) Systematic extensive laboratory studies of microbial EOR mechanisms and microbial EOR application results in Changing Oilfield. SPE Asia Pacific Oil and Gas Conference and Exhibition; Society of Petroleum Engineers, 56.
    [33] Etoumi A, Musrati IE, Gammoudi BE, et al. (2008) The reduction of wax precipitation in waxy crude oils by Pseudomonas species. J Ind Microbiol Biotechnol 35: 1241–1245. doi: 10.1007/s10295-008-0420-z
    [34] Al-Sayegh A, Al-Wahaibi Y, Al-Bahry S, et al. (2015) Microbial enhanced heavy crude oil recovery through biodegradation using bacterial isolates from an Omani oil field. Microb Cell Fact 14: 141. doi: 10.1186/s12934-015-0330-5
    [35] Kumari S, Regar RK, Manickam N (2018) Improved polycyclic aromatic hydrocarbon degradation in a crude oil by individual and a consortium of bacteria. Bioresour Technol 254: 174–179. doi: 10.1016/j.biortech.2018.01.075
    [36] Anastasi A, Coppola T, Prigione V (2009) Pyrene degradation and detoxification in soil by a consortium of basidiomycetes isolated from compost: Role of laccases and peroxidases. J Hazard Mater 165: 1229–1233. doi: 10.1016/j.jhazmat.2008.10.032
    [37] Wu M, Chen L, Tian Y, et al. (2013) Degradation of polycyclic aromatic hydrocarbons by microbial consortia enriched from three soils using two different culture media. Environ Pollut 178: 152–158. doi: 10.1016/j.envpol.2013.03.004
    [38] Zafra G, Absalón AE, Cortés-Espinosa DV (2015) Morphological changes and growth of filamentous fungi in the presence of high concentrations of PAHs. Braz J Microbiol 46: 937–941. doi: 10.1590/S1517-838246320140575
    [39] Wanapaisan P, Laothamteep N, Vejarano F, et al. (2018). Synergistic degradation of pyrene by five culturable bacteria in a mangrove sediment-derived bacterial consortium. J Hazard Mater 342: 561–570. doi: 10.1016/j.jhazmat.2017.08.062
    [40] Ghorbannezhad H, Moghimi H, Taheri RA (2018) Enhanced biodegradation of phenol by magnetically immobilized Trichosporon cutaneum. Ann Microbiol 68: 485–491. doi: 10.1007/s13213-018-1353-z
    [41] Owsianiak M., Szulc A, Chrzanowski L, et al. (2009) Biodegradation and surfactant-mediated biodegradation of diesel fuel by 218 microbial consortia are not correlated to cell surface hydrophobicity. Appl Microbiol Biot 84: 545–553. doi: 10.1007/s00253-009-2040-6
    [42] Vinithini C, Sudhakar S, Ravikumar R (2015) Biodegradation of petroleum and crude oil by Pseudomonas putida and Bacillus cereus. Int J Curr Microbiol Appl Sci 4: 318–329.
    [43] Ma Y, Wang L, Shao Z (2006) Pseudomonas, the dominant polycyclic aromatic hydrocarbon- degrading bacteria isolated from Antarctic soils and the role of large plasmids in horizontal gene transfer. Natl Cent Biotechnol Inf 8: 455–65.
    [44] Jyothi KK, Surendra B, Nancy CK, et al. (2012) Identification and Isolation of Hydrocarbon- degrading Bacteria by Molecular Characterization. Helix 2: 105–111.
    [45] El-Sayed WS (2006) Molecular cloning of gene nahH encoding extradiol-type dioxygenase from the NAH plasmid of Pseudomonas stutzeri NA1. Ann Microbiol 56: 89. doi: 10.1007/BF03174987
    [46] Veenagayathri K, Vasudevan N (2011) Ortho and meta cleavage dioxygenases detected during the degradation of phenolic compounds by a moderately halophilic bacterial consortium. Int Res J Microbiol 2: 406–414.
    [47] Zhao K, Guo X, Gong JA (2013) Novel benzoate-degrading Rhodococcus strain contains three catA genes with one being transcriptionally active during the growth on benzoate. Res J Environ Earth Sci 34: 401–407.
    [48] Dokic L, Narancic T, Nikodinovic-Runic J, et al. (2011) Four Bacillus sp. soil isolates capable of degrading phenol, toluene, biphenyl, naphthalene and other aromatic compounds exhibit different aromatic catabolic potentials. Arch Biolo Sci 63: 1057–1067.
  • This article has been cited by:

    1. Giovanni Susinni, Santi Agatino Rizzo, Francesco Iannuzzo, Two Decades of Condition Monitoring Methods for Power Devices, 2021, 10, 2079-9292, 683, 10.3390/electronics10060683
    2. Seydali Ferahtia, Ali Djeroui, Tedjani Mesbahi, Azeddine Houari, Samir Zeghlache, Hegazy Rezk, Théophile Paul, Optimal Adaptive Gain LQR-Based Energy Management Strategy for Battery–Supercapacitor Hybrid Power System, 2021, 14, 1996-1073, 1660, 10.3390/en14061660
    3. Zhonggao Yang, Dan Xiang, Yili Cheng, VR Panoramic Technology in Urban Rail Transit Vehicle Engineering Simulation System, 2020, 8, 2169-3536, 140673, 10.1109/ACCESS.2020.3009326
    4. K.M.S.Y. Konara, Mohan Kolhe, Arvind Sharma, Power flow management controller within a grid connected photovoltaic based active generator as a finite state machine using hierarchical approach with droop characteristics, 2020, 155, 09601481, 1021, 10.1016/j.renene.2020.03.138
    5. K. Raghavendra Naik, Bhooshan Rajpathak, Arghya Mitra, Mohan Lal Kolhe, Assessment of energy management technique for achieving the sustainable voltage level during grid outage of hydro generator interfaced DC Micro-Grid, 2021, 46, 22131388, 101231, 10.1016/j.seta.2021.101231
    6. Aristide Tolok Nelem, Pierre Ele, Papa Alioune Ndiaye, Salomé Ndjakomo Essiane, Mathieu Jean Pierre Pesdjock, Dynamic Optimization of Switching States of an Hybrid Power Network, 2021, 1598-6446, 10.1007/s12555-020-0088-3
    7. Seydali Ferahtia, Ali Djeroui, Hegazy Rezk, Azeddine Houari, Samir Zeghlache, Mohamed Machmoum, Optimal control and implementation of energy management strategy for a DC microgrid, 2022, 238, 03605442, 121777, 10.1016/j.energy.2021.121777
    8. Konara Mudiyanselage Sandun Y. Konara, Mohan Lal Kolhe, Nils Ulltveit-Moe, Indika A. M. Balapuwaduge, Optimal Utilization of Charging Resources of Fast Charging Station with Opportunistic Electric Vehicle Users, 2023, 9, 2313-0105, 140, 10.3390/batteries9020140
    9. Konara Mudiyanselage Sandun Y. Konara, Mohan Lal Kolhe, Queue Based Dynamic Charging Resource Allocation and Coordination for Heterogeneous Traffic in an Electrical Vehicle Charging Station, 2021, 1556-7036, 1, 10.1080/15567036.2021.1974983
    10. Ghadbane Houssam Eddine, Barkat Said, Azeddine Houari, Ali Djeroui, Tedjani Mesbahi, Hadjkaddour Abdelhak, 2022, Energy Management Strategy for Hybrid Power System Implemented with Processor in the Loop, 978-1-6654-5168-0, 1, 10.1109/CISTEM55808.2022.10043997
    11. Konara Mudiyanselage Sandun Y. Konara, Mohan Lal Kolhe, Nils Ulltveit-Moe, Indika A. M. Balapuwaduge, Reliability Enhancement of Fast Charging Station under Electric Vehicle Supply Equipment Failures and Repairs, 2023, 16, 1996-1073, 2933, 10.3390/en16062933
    12. Shaibu Ali Juma, Sarah Paul Ayeng'o, Cuthbert Z. M. Kimambo, A review of control strategies for optimized microgrid operations, 2024, 18, 1752-1416, 2785, 10.1049/rpg2.13056
    13. Hegazy Rezk, Ahmed Fathy, Hydrogen reduction-based energy management strategy of hybrid fuel cell/PV/battery/supercapacitor renewable energy system, 2024, 86, 2352152X, 111316, 10.1016/j.est.2024.111316
    14. Seydali Ferahtia, Azeddine Houari, Tudor Cioara, Mohammed Bouznit, Hegazy Rezk, Ali Djerioui, Recent advances on energy management and control of direct current microgrid for smart cities and industry: A Survey, 2024, 368, 03062619, 123501, 10.1016/j.apenergy.2024.123501
    15. Houssam Eddine Ghadbane, Said Barkat, Azeddine Houari, Ali Djerioui, Hadjkaddour Abdelhak, Tedjani Mesbahi, A Load Following Energy Management Strategy for a Battery-Supercapacitor Hybrid Power System Implemented with a PIL Co-Simulation Approach, 2024, 9, 2731-8087, 10.1007/s40866-024-00214-4
    16. Badreddine Kanouni, Abd Essalam Badoud, Saad Mekhilef, Mohit Bajaj, Ievgen Zaitsev, Advanced efficient energy management strategy based on state machine control for multi-sources PV-PEMFC-batteries system, 2024, 14, 2045-2322, 10.1038/s41598-024-58785-2
    17. Ali Falih Challoob, Nur Azzammudin Bin Rahmat, Vigna Kumaran A/L Ramachandaramurthy, Amjad Jaleel Humaidi, Energy and battery management systems for electrical vehicles: A comprehensive review & recommendations, 2024, 42, 0144-5987, 341, 10.1177/01445987231211943
    18. M. Hilmi, Vita Lystianingrum, Mohd Fakhizan Romlie, 2024, Energy Management System Based on Finite State Machine for Battery-Supercapacitor Hybrid Energy Storage System on Standalone Photovoltaic, 979-8-3503-4457-8, 91, 10.1109/ICPEA60617.2024.10498346
    19. Mohamed Zine Zizoui, Bekheïra Tabbache, Muhammad Fahad Zia, Mohamed Benbouzid, Control and Management Approach of Photovoltaic-Battery-Ultra-Capacitor Energy System in Standalone and Grid-Connected Modes, 2024, 70, 0377-2063, 6318, 10.1080/03772063.2023.2284951
  • Reader Comments
  • © 2019 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Metrics

Article views(5988) PDF downloads(1010) Cited by(29)

Figures and Tables

Figures(10)

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return

Catalog