Citation: Arosh S. Perera Molligoda Arachchige. 7-Tesla PET/MRI: A promising tool for multimodal brain imaging?[J]. AIMS Neuroscience, 2022, 9(4): 516-518. doi: 10.3934/Neuroscience.2022029
[1] | Arosh S. Perera Molligoda Arachchige . Transitioning from PET/MR to trimodal neuroimaging: why not cover the temporal dimension with EEG?. AIMS Neuroscience, 2023, 10(1): 1-4. doi: 10.3934/Neuroscience.2023001 |
[2] | Arosh S. Perera Molligoda Arachchige, Anton Kristoffer Garner . Seven Tesla MRI in Alzheimer's disease research: State of the art and future directions: A narrative review. AIMS Neuroscience, 2023, 10(4): 401-422. doi: 10.3934/Neuroscience.2023030 |
[3] | Kevin Pierre, Vanessa Molina, Shil Shukla, Anthony Avila, Nicholas Fong, Jessica Nguyen, Brandon Lucke-Wold . Chronic traumatic encephalopathy: Diagnostic updates and advances. AIMS Neuroscience, 2022, 9(4): 519-535. doi: 10.3934/Neuroscience.2022030 |
[4] | Nisha Syed Nasser, Krish Sharma, Parv Mahendra Mehta, Vidur Mahajan, Harsh Mahajan, Vasantha Kumar Venugopal . Estimation of white matter hyperintensities with synthetic MRI myelin volume fraction in patients with multiple sclerosis and non-multiple-sclerosis white matter hyperintensities: A pilot study among the Indian population. AIMS Neuroscience, 2023, 10(2): 144-153. doi: 10.3934/Neuroscience.2023011 |
[5] | Mark Reed, Christopher Miller, Cortney Connor, Jason S. Chang, Forshing Lui . Fat droplets in the cerebrospinal fluid (CSF) spaces of the brain. AIMS Neuroscience, 2024, 11(4): 484-489. doi: 10.3934/Neuroscience.2024029 |
[6] | Graziella Orrù, Marina Baroni, Ciro Conversano, Angelo Gemignani . Exploring the therapeutic potential of tDCS, TMS and DBS in overcoming tobacco use disorder: an umbrella review. AIMS Neuroscience, 2024, 11(4): 449-467. doi: 10.3934/Neuroscience.2024027 |
[7] | Jonathan R. Emerson, Jack A. Binks, Matthew W. Scott, Ryan P. W. Kenny, Daniel L. Eaves . Combined action observation and motor imagery therapy: a novel method for post-stroke motor rehabilitation. AIMS Neuroscience, 2018, 5(4): 236-252. doi: 10.3934/Neuroscience.2018.4.236 |
[8] | Daniel Chimuanya Ugwuanyi, Tochukwu Florence Sibeudu, Chidmma Precious Irole, Michael Promise Ogolodom, Chukwudi Thaddeus Nwagbara, Adaobi Maryann Ibekwe, Awajimijan Nathaniel Mbaba . Evaluation of common findings in brain computerized tomography (CT) scan: A single center study. AIMS Neuroscience, 2020, 7(3): 311-318. doi: 10.3934/Neuroscience.2020017 |
[9] | María González-Sánchez, María Jesús Ramírez-Expósito, José Manuel Martínez-Martos . Infantile neuroaxonal dystrophy: Molecular mechanisms and pathogenesis of PLA2G6-associated neurodegeneration. AIMS Neuroscience, 2025, 12(2): 180-202. doi: 10.3934/Neuroscience.2025011 |
[10] | Milad Khodavysi, Nejat Kheiripour, Hassan Ghasemi, Sara Soleimani-Asl, Ali Fathi Jouzdani, Mohammadmahdi Sabahi, Zahra Ganji, Zahra Azizi, Akram Ranjbar . How can nanomicelle-curcumin modulate aluminum phosphide-induced neurotoxicity?: Role of SIRT1/FOXO3 signaling pathway. AIMS Neuroscience, 2023, 10(1): 56-74. doi: 10.3934/Neuroscience.2023005 |
The dawn of ultra-high field imaging has undoubtedly shown its value in both research and clinical practice especially in cognitive neuroimaging. Scientists have long made an effort to incorporate the anatomical, functional, blood flow information provided by MRI with metabolic, molecular information provided by PET in order to establish new connections among them and have so far made a huge progress. This is because in PET/CT, the CT examination adds a substantial X-ray dose which has been shown through several studies to easily rise above the dose from an applied PET isotope to even result in altered immune responses or biological pathways in animal models, and is significantly large enough to cause a radiotherapy treatment like effect in studies investigating the effectiveness of novel anti-tumor drugs potentially obscuring their results [1]. Furthermore, PET/MRI offers better soft tissue contrast over PET/CT in specific regions such as the brain parenchyma and has shown to be even greater with higher field strengths since gains in signal-to-noise or contrast-to-noise ratio and greater spatial resolution have allowed finer structures to be visualized and smaller physiological effects to be detected compared to lower field systems. Also, PET/MRI provides greater flexibility in terms of the plurality of sequences [2].
Mayo Clinic was the first centre in North America to use clinical 7-tesla MRI, after the system was approved in 2017. Currently, Mayo Clinic uses both positron emission tomography (PET) scans and 7-tesla MRI to image individuals with epilepsy to identify potential candidates for surgical treatment. Here, they use 7T imaging if initial PET scans and 3-tesla MRI indicate metabolic abnormalities associated with seizure-origin sites as well as potential suspect lesions which according to them has allowed to detect 20–30% of lesions that went undetected with 3T [3]. This is an example of asynchronous multimodality imaging which aims to combine morpho-functional information by acquiring images at different times, and fuse them through digital image manipulation techniques. This however comes with a set of constraints, mainly conditioned by the different positioning of the patient in the two scans acquired at different times in separated machines [4]. Even if the two scanners are mounted in-line in a common gantry and with a single patient couch, attenuation correction will be required and thus results in lengthy transmission scans and increased patient throughputs [5]. On the contrary, synchronous image acquisition being a one-stop-shop procedure allows to achieve consistency in time and space. It has benefits in terms of patient comfort, decreased demand on instrumental and administrative resources and could be especially advantageous in dementia patients with reduced ability to cooperate [4],[5]. Although there are clear differences between the two, the motivation to integrate PET and MRI was the huge success derived from PET/CT. Such PET/MRI technology has been efficiently utilized at conventional field strengths in the context of several neurological conditions such as Alzheimer's disease, Parkinsonian syndromes, multiple sclerosis, brain tumors, epilepsy, etc [6].
So, in what ways does the incorporation of ultra-high field imaging benefit? A study by Hammer et al. showed that magnetic field strengths above 5T can further improve PET image quality by reducing the mean free positron path between emission and annihilation and this has been made possible since latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields [7]. Indeed, the 7T PET-MRI, the very latest innovation in preclinical imaging of animal models is a PET system coupled with (a cryogen-free) 7T MRI that enables simultaneous PET and MR imaging data acquisition. To our knowledge, 7T PET/MRI is currently manufactured exclusively by “MR Solutions (UK)” and is already available in a few countries notably the US, Norway, and Israel [8]. Additionally, in a study by Cho et al. where a PET/MRI system consisting of a HRRT (high-resolution research tomograph; a human brain PET scanner) and a 7T MR scanner were operated for in-vivo visualization of thalamic subnucleus quantitative glucose metabolism, the high-resolution, high-contrast images of the 7T MR component scanner enabled in-detail discrimination of the thalamic nuclei, allowing precise localization of the corresponding in vivo metabolic activities obtained by the HRRT. This PET molecular imaging system could be useful in investigating mechanisms of pain or it could be extended to D2 receptor distribution in each thalamic nucleus in imaging of Parkinsonian syndromes, and many more [9]. These are just a few studies to mention, and many more studies are yet to come with the adequate distribution of the 7T PET/MRI facilities globally. If this tool is to have widespread impact outside a small group of academic sites, training the next generation of technicians and interpreters is a challenge which will have to be met. According to Catana et al. one of the main challenges, the limited space available inside the bore of standard MR systems to integrate the PET detectors, has been solved by introducing larger bore diameters that provided adequate space [10]. However, we found no evidence explaining why 7T PET/MRI with large bore sizes in order for them to be used in the clinic are not yet available. We assume that it has been due to the lack of adequate studies highlighting the clinical potential of this new multimodality imaging tool. In addition, more research is needed to determine the cost effectiveness of PET-MR technology. We are confident that it will be possible to translate these technologies used in preclinical studies to human PET/MRI scanners with 7-T or higher-field magnets through further technologic developments and appropriate modifications, which will lead the next generation of molecular imaging.
[1] |
Pichler BJ, Judenhofer MS, Wehrl HF (2008) PET/MRI hybrid imaging: devices and initial results. Eur Radiol 18: 1077-1086. https://doi.org/10.1007/s00330-008-0857-5 ![]() |
[2] | Brix G, Noke D, Lechel U (2005) Radiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations. J Nucl Med 46: 608-613. |
[3] | Combining PET scans and 7-tesla MRI to pinpoint subtle epileptogenic lesions - Mayo Clinic. https://www.mayoclinic.org/medical-professionals/neurology-neurosurgery/news/combining-pet-scans-and-7-tesla-mri-to-pinpoint-subtle-epileptogenic-lesions/mac-20519067. |
[4] |
Martí-Bonmatí L, Sopena R, Bartumeus P, et al. (2010) Multimodality imaging techniques. Contrast Media Mol I 5: 180-189. https://doi.org/10.1002/cmmi.393 ![]() |
[5] |
Vandenberghe S, Marsden PK (2015) PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging. Phys Med Biol 60: R115-R154. https://doi.org/10.1088/0031-9155/60/4/R115 ![]() |
[6] |
Yang ZL, Zhang LJ (2016) PET/MRI of central nervous system: current status and future perspective. Eur Radiol 26: 3534-3541. https://doi.org/10.1007/s00330-015-4202-5 ![]() |
[7] |
Hammer BE, Christensen NL, Heil BG (1994) Use of a magnetic field to increase the spatial resolution of positron emission tomography. Med Phys 21: 1917-1920. https://doi.org/10.1118/1.597178 ![]() |
[8] | Preclinical PET/MRI 7T Simultaneous imaging. (n.d.).. Preclinical PET/MRI 7T Simultaneous Imaging . Available from https://www.mrsolutions.com/molecular-imaging/molecular-imaging/pet-mr-cryogen-free/petmr-7t/ (Retrieved December 6, 2022) |
[9] |
Cho ZH, Son YD, Kim HK, et al. (2011) Observation of glucose metabolism in the thalamic nuclei by fusion PET/MRI. J Nucl Med 52: 401-404. https://doi.org/10.2967/jnumed.110.081281 ![]() |
[10] |
Catana C, Guimaraes AR, Rosen BR (2013) PET and MR imaging: the odd couple or a match made in heaven?. J Nucl Med 54: 815-824. https://doi.org/10.2967/jnumed.112.112771 ![]() |
1. | Arosh S Perera Molligoda Arachchige, Sarah Meuli, Francesca Romana Centini, Niccolò Stomeo, Federica Catapano, Letterio S Politi, Evaluating the role of 7-Tesla magnetic resonance imaging in neurosurgery: Trends in literature since clinical approval, 2024, 16, 1949-8470, 274, 10.4329/wjr.v16.i7.274 | |
2. | Arosh S. Perera Molligoda Arachchige, Neuroimaging with PET/MR: moving beyond 3 T in preclinical systems, when for clinical practice?, 2023, 11, 2281-7565, 315, 10.1007/s40336-023-00572-6 | |
3. | Taofeng Xie, Chentao Cao, Zhuo‐xu Cui, Yu Guo, Caiying Wu, Xuemei Wang, Qingneng Li, Zhanli Hu, Tao Sun, Ziru Sang, Yihang Zhou, Yanjie Zhu, Dong Liang, Qiyu Jin, Hongwu Zeng, Guoqing Chen, Haifeng Wang, Synthesizing PET images from high‐field and ultra‐high‐field MR images using joint diffusion attention model, 2024, 51, 0094-2405, 5250, 10.1002/mp.17254 | |
4. | Arosh S. Perera Molligoda Arachchige, Niccolò Stomeo, Rethinking Patient Communication in Radiology and Nuclear Medicine: Striking a Balance for Optimal Care, 2023, 12, 2281-7565, 225, 10.1007/s40336-023-00600-5 | |
5. | Arosh S Perera Molligoda Arachchige, Ana Claudia Teixeira de Castro Gonçalves Ortega, Federica Catapano, Letterio S Politi, Michael N Hoff, From strength to precision: A systematic review exploring the clinical utility of 7-Tesla magnetic resonance imaging in abdominal imaging, 2024, 16, 1949-8470, 20, 10.4329/wjr.v16.i1.20 | |
6. | Arosh S Perera Molligoda Arachchige, Letterio S Politi, Potential applications of 7 Tesla magnetic resonance imaging in paediatric neuroimaging: Feasibility and challenges, 2024, 13, 2219-2808, 10.5409/wjcp.v13.i2.90641 | |
7. | Yaohui Wang, Pengfei Wu, Wenchen Wang, Hui Wang, Shunzhong Chen, Jinshui Sun, Feng Liu, Cryogen-free superconducting magnetic resonance imaging system: A review, 2025, 26673258, 10.1016/j.fmre.2025.05.006 |