Review Topical Sections

Piezoelectric cellular polymer films: Fabrication, properties and applications

  • Piezoelectricity can be defined as the ability of certain materials to provide mechanical–electrical energy conversion. In addition to traditional ferroelectric polymers (such as polyvinylidene fluoride, PVDF) and ceramics (such as lead zirconate titanate, PZT), charged polymer film foams have also shown important piezoelectric activity. In fact, when cellular polymers are exposed to high electrical fields, positive and negative charges are created on the opposite faces of each cell surface. As a result, charged cellular polymers can exhibit ferroelectric-like behavior and may therefore be called ferroelectrets. The piezoelectric effect of these materials is known to be affected by several parameters such as the cellular structure (cell density, shape and size), relative density and elastic stiffness. However, a careful morphology control is mandatory to optimize the piezoelectric response.
    Ferroelectrets have recently received a great deal of academic and industrial interest due to their wide range of technological applications associated with high piezoelectric constants, low cost, flexibility and low weight. In this paper, an overview of different piezoelectric cellular polymers is presented with recent developments and applications.

    Citation: Ouassim Hamdi, Frej Mighri, Denis Rodrigue. Piezoelectric cellular polymer films: Fabrication, properties and applications[J]. AIMS Materials Science, 2018, 5(5): 845-869. doi: 10.3934/matersci.2018.5.845

    Related Papers:

    [1] Jian Zhang, Zhonghua Gou, Leigh Shutter . Effects of internal and external planning factors on park cooling intensity: field measurement of urban parks in Gold Coast, Australia. AIMS Environmental Science, 2019, 6(6): 417-434. doi: 10.3934/environsci.2019.6.417
    [2] M.A. Rahim, M.G. Mostafa . Impact of sugar mills effluent on environment around mills area. AIMS Environmental Science, 2021, 8(1): 86-99. doi: 10.3934/environsci.2021006
    [3] Alejandra S. Coronel, Susana R. Feldman, Emliano Jozami, Kehoe Facundo, Rubén D. Piacentini, Marielle Dubbeling, Francisco J. Escobedo . Effects of urban green areas on air temperature in a medium-sized Argentinian city. AIMS Environmental Science, 2015, 2(3): 803-826. doi: 10.3934/environsci.2015.3.803
    [4] Dominic Bowd, Campbell McKay, Wendy S. Shaw . Urban greening: environmentalism or marketable aesthetics. AIMS Environmental Science, 2015, 2(4): 935-949. doi: 10.3934/environsci.2015.4.935
    [5] Ammon Boswell, Steven Petersen, Bruce Roundy, Ryan Jensen, Danny Summers, April Hulet . Rangeland monitoring using remote sensing: comparison of cover estimates from field measurements and image analysis. AIMS Environmental Science, 2017, 4(1): 1-16. doi: 10.3934/environsci.2017.1.1
    [6] Hoa T. Trinh, Peter Adriaens, Christian M. Lastoskie . Fate factors and emission flux estimates for emerging contaminants in surface waters. AIMS Environmental Science, 2016, 3(1): 21-44. doi: 10.3934/environsci.2016.1.21
    [7] Pasquale Marcello Falcone, Grazia Errichiello . Energy Justice in the 21st century: policy interventions and advocacy for a fair energy transition. AIMS Environmental Science, 2025, 12(4): 594-614. doi: 10.3934/environsci.2025027
    [8] Piyush S. Desai, Falguni P. Desai . An overview of sustainable green inhibitors for aluminum in acid media. AIMS Environmental Science, 2023, 10(1): 33-62. doi: 10.3934/environsci.2023003
    [9] Abigail W. Porter, Sarah J. Wolfson, Lily. Young . Pharmaceutical transforming microbes from wastewater and natural environments can colonize microplastics. AIMS Environmental Science, 2020, 7(1): 99-116. doi: 10.3934/environsci.2020006
    [10] Krittiya Singcharoen, Ratthapol Rangkupan, Soontree Khuntong, Thanakorn Wasanapiarnpong . Enhancing photocatalytic efficiency with Mn-doped ZnO composite carbon nanofibers for organic dye degradation. AIMS Environmental Science, 2024, 11(2): 324-341. doi: 10.3934/environsci.2024015
  • Piezoelectricity can be defined as the ability of certain materials to provide mechanical–electrical energy conversion. In addition to traditional ferroelectric polymers (such as polyvinylidene fluoride, PVDF) and ceramics (such as lead zirconate titanate, PZT), charged polymer film foams have also shown important piezoelectric activity. In fact, when cellular polymers are exposed to high electrical fields, positive and negative charges are created on the opposite faces of each cell surface. As a result, charged cellular polymers can exhibit ferroelectric-like behavior and may therefore be called ferroelectrets. The piezoelectric effect of these materials is known to be affected by several parameters such as the cellular structure (cell density, shape and size), relative density and elastic stiffness. However, a careful morphology control is mandatory to optimize the piezoelectric response.
    Ferroelectrets have recently received a great deal of academic and industrial interest due to their wide range of technological applications associated with high piezoelectric constants, low cost, flexibility and low weight. In this paper, an overview of different piezoelectric cellular polymers is presented with recent developments and applications.


    Architecture, urban planning and design, and the behavior of residents will affect the urban environment and climate. The large-scale and rapid development of cities and the rapid growth of urban population bring about the unreasonable distribution of resources, which makes the urban climate and environment of our country change greatly. These changes affect the energy consumption of urban buildings and the physical and mental health of residents in all aspects. The key of building and urban design is to create a suitable living environment. As an important place for outdoor activities of urban residents, the quality of thermal environment of commercial street directly affects the quality of life of residents, and plays a very important role in regulating regional microclimate. In recent years, people continue to pay attention to the concept of sustainable development, and the research on urban microclimate is more and more extensive, among which the research on urban street space and ecological environment is also gradually deepened.

    The study of outdoor microclimate started early, and has formed a theoretical system related to urban design and microclimate, especially how to consider the impact of climate factors in the design process, and has carried out a lot of research in different climate regions, and has made rich achievements. Among them, the research elements of outdoor microclimate mainly include the height width ratio of street, street trend, greening and the characteristics of underlying surface. For example, shashua-bar [1] and others have carried out a series of studies on the street valley with trees based on the CTTC model. The results show that the addition of trees is very effective to improve the microclimate and thermal comfort. In the street valley with trees, the canopy plays a major role in shading, the addition of trees increases the CTTC value, and the daily change of temperature slows down. The cooling effect of trees mainly depends on the shadow coverage, and the tree coverage also affects the Improving the thermal environment of streets plays a key role. Andrew M. Coutts [2] et al. Studied the thermal environment of different street valleys through field measurement, and proposed that the impact of trees in street valleys on air temperature and human thermal comfort is different, which depends on tree coverage, geometry and relevant climatic conditions. When the height width ratio of the street is small, the cooling effect of the tree canopy is more obvious, so choosing appropriate tree planting density and tree species can be used as the strategy to improve the microclimate of the street. Toudertr [3] points out that the shading effect of trees on solar radiation is affected by leaf area index and solar radiation through light path, which in turn affects the effect of trees on reducing Street thermal effect. The improvement depends largely on LAD, LAI and geometry. Low density trees produce less shadows but allow more air flow. Morakinyor [4] simulated the thermal environment of LAI and LAD under different wind speeds through Envi-met, and proposed that in addition to the LAI and LAD of trees, the arrangement form of trees is also an important factor, and the trees arranged in two rows have a greater impact than those arranged in the center of a single row. Oke [5] pointed out that the air temperature in the park is nearly 3K lower than that of the surrounding urban canopy, and the influence range is extensible; Stella Tsokar [6] measured and simulated the influence of different underlying surfaces on the microclimate and physiological equivalent temperature (PET) of the urban climate space, and the research shows that the influence of different underlying materials on the solar reflection coefficient is different, and the greening can effectively reduce the solar reflection coefficient in the street valley space. Kubota T [7] put forward the method of using building coverage to achieve acceptable wind environment index of residential quarters by analyzing the wind tunnel test results of 22 residential quarters in Japan.

    The research on outdoor microclimate started late in China. Jingyuan Zhao [8] of Chang'an University in Xi'an studied the improvement effect of trees on the thermal environment with WBGT and set as indicators. He pointed out that the improvement of trees on the thermal environment was mainly caused by the shade of canopy on the solar radiation, and the effect of trees on the improvement of the thermal environment of street valley was the most significant, followed by lawn, and shrub. Zhen Wang [9] put forward the greening design of the underlying surface of the block gap, which is conducive to improving the microclimate of the gap in summer. Increasing the area of green space appropriately can also improve the microclimate of the block gap. Haiping Liu [10] studied the influence of different greening types on the thermal environment of Shanghai residential area by simulation, and concluded that under the premise of the same greening coverage rate, the combination of trees, shrubs and grass bottom has a more obvious cooling effect on the residential area. Tobi Eniolu Morakinyo [11] studied the influence of greening species and greening rate on microclimate in Mongkok area of Kowloon Peninsula, Hong Kong. It is recommended to plant high trees with low canopy in the street valley of Hong Kong. Yingsheng Zheng [12] selected three types of areas in the research area of Tai Pu ruins, namely, multi-layer high-density area, high-rise medium density area, and open area, to analyze the wind environment of pedestrian floor height, and then, on the premise of high-density construction, established new models to simulate and verify the feasibility of improving regional summer ventilation by optimizing the urban morphology.

    Based on the summary of the research status at home and abroad, it is found that although a large number of urban microclimate studies have been carried out under different climate conditions at home and abroad, and very rich research results have been achieved, but the research on urban microclimate in high-altitude and cold areas is less, especially for the research on microclimate in high-altitude and cold areas. The research mainly focuses on the microclimate related research at the architectural scale, for example, Xinrong Zhu [13] has made some research achievements in the construction system of Tibet Plateau, Ya Feng [14] studied heating system and natural energy utilization, Quan He [15] studied ecological attribute in residential buildings, and Songtao Hu [16] experimental research on thermal comfort in high altitude areas. Although there have been a lot of research results on single building, however the research on urban block scale is still lacking in Tibet. Therefore, the purpose of this paper is to study the impact of the layout of the underlying surface of the street on the thermal environment of the street in Lhasa, hoping to provide reference for the future urban planning and design in Lhasa through the analysis and consideration of the test data.

    Lhasa, 29°36′ north latitude and 91°13′ east longitude, is located on the Qinghai-Tibet Plateau with an altitude of about 3648 m. It is one of the highest cities in the world, which belongs to the cold climate zone according to the zoning of China's architectural climate region. It also belongs to plateau temperate semi-arid monsoon climate zone. Lhasa area has a cold and dry climate, less annual precipitation, low relative humidity in spring and winter, and southwest gale in winter. The vertical climate changes obviously. The annual sunshine hours can reach more than 3000 hours, and the solar radiation is very strong. So, it is known as "Sunshine City".

    (1) Basic characteristics of streets

    The buildings on both sides of the street surveyed are mostly low-rise buildings and multi-storey buildings, dominated by multi-storey without high-rise buildings. The main types of buildings are commercial buildings and public buildings, dominated by commercial buildings with the first floor mainly for business use and the second floor for living. Most of the building materials are light-colored tiles, dominated by red, white and gray. The street direction is mainly east-west and north-south. Due to the urban planning control in Lhasa, the Height-width ratio (H/W) of Lhasa street is generally less than 1, and mainly between 0.2 and 0.5. It is impossible to form the deep street canyon space just as other cities. The pedestrian road is mainly paved with gray tiles.

    (2) Arrangement of greening

    The street trees in the surveyed pedestrian space are basically arranged in the form of interval and the combination of trees and shrubs. The distance between the trees is not equal, ranging from 4 to 8 m. The trees are mainly willow, poplar and elm, but there is no uniform standard for tree selection for Lhasa streets. Thus, some trees are unable to ease the thermal discomfort of pedestrians in the summer.

    (3) Arrangement of water area

    In terms of water area, there is only one form of fountain in the surveyed area with two fountains on the north side of Yutuo Road and one fountain on the south side of Bakuo Street. The fountain opens during daytime in summer, creating a local cool microclimate to attract people to stay around.

    Through the large-scale investigation of Lhasa streets in the early stage, three streets in the same area, east-west, and north-south direction were selected for actual measurement. The principle of selecting measurement sites is that there are different underlying surface elements for preliminary comparative analysis. Secondly, considering the influence of artificial heat sources and vehicle emission heat sources, three commercial streets are selected, namely Yutuo Road, Duosen road and Hongqi Road. The characteristics of each street are shown in Table 1.

    Table 1.  Description of the street property (Data source: field survey).
    Name of street Yutuo road South Duosen road Hongqi road
    Street direction E-W N-S E-W
    The number of measuring point 5 4 2
    Minimum building height (m) 12 12 7
    Maximum building height (m) 17 7 14
    Average building eeight (m) 15 9 11
    Street width (m) 45 34 23
    Average height-width ratio 0.3 0.26 0.47

     | Show Table
    DownLoad: CSV

    In order to avoid the influence of external factors on the experimental results and ensure the accuracy and effectiveness of the measurement results, the selection and arrangement of measurement points shall follow the following principles:

    (1) Minimize the Interference of People and Vehicles on the Experimental Results

    Crowd movement and vehicle exhaust emissions will affect the surrounding environment. Therefore, in the selection and layout of measurement points, we choose the location with less pedestrian volumes and traffic volumes to ensure the accuracy of measurement results.

    (2) Ensure the Unity of the External Environment

    In microclimate measurement, the differences of underlying surface, height-width ratio (H/W) of surrounding buildings, street orientation, greening and other factors will affect the experimental results. Therefore, we try our best to ensure the unity of the external environment, and reduce the impact and error caused by the difference of the external environment in the same experimental scheme.

    (1) Layout of measuring points on Yutuo Road: measuring point 1 was arranged next to the fountain on the north side of Yutuo Road, measuring point 2 was arranged under the tree shade of the north side of Yutuo Road, measuring point 3 was arranged in the shadeless area, measuring point 4 was arranged under the tree shade of the south side of Yutuo Road, and the measuring point 5 was arranged outside the tree.

    (2) Layout of the measuring points on Duosen Road: The measuring point 6 was arranged in the area without tree shade on the west side of the Duosen Road, the measuring point 7 was arranged in the tree shade which is not far from the measuring point 6, the measuring point 8 was arranged under the shade on the east side of the South Duosen Road, and the measuring point 9 was arranged in a shadeless area.

    (3) Layout of measuring points on Hongqi Road: The measuring point 11 was arranged under the shade of the south side of Hongqi Road, and the leaf area index of the trees is small. The measuring point 10 was arranged in the area without tree shade on the south side of the Hongqi Road.

    Figure 1.  The arrangement of measuring points (Left is Yutuo road-Duosen road, right is Hongqi road).
    Figure 2.  Fisheye photographs of each measuring.
    Table 2.  Measuring point information.
    H/W SVF Tree species Details
    1 0.45 0.802 —— Fountain
    2 0.45 0.42 Elm Below tree
    3 0.45 0.79 —— Outside tree
    4 0.45 0.49 Elm Below tree
    5 0.45 0.77 —— Outside tree
    6 0.31 0.73 —— Outside tree
    7 0.31 0.42 Poplar Below tree
    8 0.31 0.44 Poplar Below tree
    9 0.31 0.74 —— Outside tree

     | Show Table
    DownLoad: CSV

    In this field measurement, the measurement points of different underlying surface structures of pedestrian street are tested for 4 consecutive days in winter and summer. According to the hourly meteorological data provided by Lhasa Meteorological Bureau, one day with similar meteorological conditions was selected as the effective date. The final test date was June 26, 2017 and December 7, 2017. The measurement time during the test was 10:00–20:00. The test contents include air temperature, relative humidity, wind speed, black ball temperature and solar radiation at the pedestrian height (1.5 m above the ground) of each measuring point. The instruments used for the test are shown in Figure 3, and the parameters of each instruments are shown in Table 3.

    Figure 3.  Test instruments.
    Table 3.  Test instruments and accuracy.
    Measurement parameters Instrument Instrument parameters Acquisition time
    Air temperature relative humidity Temperature and humidity recorder model: GSP958 Temperature Measurement Range: − 40–85 ℃;
    Accuracy: − 20–40 ℃, ± 0.5 ℃;
    Humidity Measurement Range: 0–99.9% RH;
    Accuracy: ± 3% RH;
    5 mins
    Wind speed Portable anemometer model: WFWZY-1 Instrument range: 0.05–30 m/s
    Accuracy: 5% ± 0.05m/s (0.05–30 m/s)
    15 mins
    Black sphere temperature Black sphere thermometer model: HQZY-1 Measurement range: − 20–80 ℃;
    Accuracy: ± 0.3 ℃ (−40–60 ℃)
    5 mins
    Solar radiation Solar radiometer model: SPN1 Overall accuracy: total radiation and scattering ± 5% (daily integration);
    ± 5% ± 10W/m2 (hourly average)
    15 mins
    Thermal comfort instrument Model: JI-IAQ Wind speed measurement range: 0.05–5 m/s, Accuracy: ± (0.03m/S + 2 & reading),
    Humidity measurement range: 0–100% RH, Accuracy: ± 1.5% RH,
    Black sphere temperature range: 5–120 ℃, Accuracy: ± 0.5 ℃ (5–50 ℃)
    5 mins

     | Show Table
    DownLoad: CSV

    (1) Street height-width ratio (H/W)

    The height-width ratio (H / W) of street valley refers to the ratio of the average width of buildings on both sides of street valley (the elevation of adjacent vertical buildings) to the width of street valley (the width from wall to wall across the street), which reflects the compactness and opening degree of Street [9] (Figure 4). In addition to the direct psychological feeling, the aspect ratio has a direct impact on the microclimate index of the street valley, such as the solar radiation area of the street valley.

    Figure 4.  H/W.
    Figure 5.  Sky view factor.

    (2) Sky view factor (SVF)

    In the field of architecture and urban design, the definition based on geometric form is the ratio of visible sky to all day sky for a given point; from the perspective of climate, the definition based on sky is the ratio of the ratio of blessing flux emitted to the sky on a plane to the total blessing flux [17]. The estimation of sky visibility factors mainly includes geometric mathematical analysis, fisheye lens photography, and total blessing ball positioning system method and software calculation method [18].

    (3) Leaf area index (LAI)

    Leaf area index refers to the multiple of the total area of plant leaves in the land per unit land area, which directly determines the difference of plant on the solar penetration rate [19], water transpiration capacity and other aspects, and then the impact on the thermal environment. Leaf area index refers to the total plant leaf area (m2) per unit community volume (m3). The relationship between leaf area density and leaf area index is LAI=h0LAD.Δz(where h is the height of the tree (m) and △Z is the vertical grid size) [20].

    (4) Mean radiant temperature (MRT)

    The mean radiant temperature is defined as the surface temperature of an imaginary isothermal enclosure surface. The radiant heat exchange between the surface and the human body is equal to the actual radiant heat exchange between the non-isothermal enclosure surface around the human body and the human body, reflecting the radiant heat exchange between the human body and the surrounding environment. The calculation formula is as follows [21]:

    Tmrt=[(Tg+273.15)4+1.1×108V0.6aεD0.4×(TgTa)]1/4273.15

    where Tg is the globe temperature, v is wind velocity (m. s−1), D is the globe diameter (m), ɛ is the globe emissivity (0.95), and Ta is air temperature.

    (5) Physiological equivalent temperature (PET)

    In this paper, the physiological equivalent temperature pet is calculated by using the software Rayman. The PET of the measuring point can be obtained by inputting the measured temperature, humidity, wind speed, radiation temperature and other parameters into Rayman. The classification range of physiological equivalent temperature PET is as follows (Table 4) [22], PET can directly reflect the human thermal feeling in a certain environment. Human body is comfortable at 18–23 ℃.

    Table 4.  Outdoor thermal comfort classification table (Table source: [22]).
    PET (℃) Thermal comfort Physiological stress
    < 4 Very cold Extreme cold stress
    4–8 Cold Severe cold stress
    8–13 Cool Moderate cold stress
    13–18 Slightly cool Mild cold stress
    18–23 Comfort No thermal stress
    23–29 Slightly warmer Mild heat stress
    29–35 Warm Moderate heat stress
    35–41 Hot Strong heat stress
    > 41 Very hot Extreme heat stress

     | Show Table
    DownLoad: CSV

    In order to ensure the accuracy of the data, the datas from 10:00 to 19:00 were selected as the effective datas of the actual measurement and analysis. The meteorological parameters analyzed in this experiment mainly including air temperature, relative humidity, wind speed, black sphere temperature, solar radiation and average radiation temperature. In addition, the physiological equivalent temperature (PET), an outdoor thermal comfort evaluation index, was introduced to analyze the microclimate impact of greening and water area on the local space of the street from four aspects: the same side of the same street, the different sides of the same street, the streets with different directions, and the water area. The specific results are as follows.

    The impacts of greening on the street thermal environment of the same side of the same street were compared. The measuring point 2 (under the tree shade) and the measuring point 3 (without shade) on the north side of the east-west Yutuo Road, the measuring point 4 (under the tree shade) and the measuring point 5 (without shade) on the south side of the road, the measuring point 6 (without shade) and measuring point 7 (under the shade) on the west side of the south-north Duosen Road, measuring point 8 (under the shade) and measuring point 9 (no shade) on the east side of the road were selected. The measuring points under the shade and outside the shade on the same side of the same street were compared pairwise, as shown in Figure 6a, b below. The analysis can be obtained.

    Figure 6a.  Measured drawing of measuring points on the same side of the same street.
    Figure 6b.  Measured drawing of measuring points on the same side of the same street.

    In summer, the measuring points 3, 5, 6, and 9 without tree shade are under direct solar radiation, and their air temperature, solar radiation value, black sphere temperature value, and average radiation temperature are higher than those measured under the shade of trees. The time of PET value in the "comfortable" thermal sensation is also significantly shorter. The relative humidity of each measuring point corresponds to the temperature. The higher the temperature, the lower the humidity. The average humidity of the four measuring points under the shade is greater than that of the measuring points without shade, suggesting the obvious effect of trees on cooling and humidifying the street thermal environment. Similarly, by comparing the average wind speed of the four pairs of measuring points, it can be found that the average wind speed of the measuring points under the shade can be slightly smaller, and the shielding of the trees has a certain effect on the wind speed, but the influence is relatively small.

    In winter, due to the shielding of buildings, the measuring points on the south and north side of Yutuo Road received uneven solar radiation and the temperature difference is significant. The air temperature, black sphere temperature and average radiation temperature of the measuring point 2 (under the shade) on the north side of the road are lower than those of measuring point 3 outside the shade, and the time of PET value in the "comfortable" thermal sensation is longer. All of those indicating that although the leaf fall in the winter causes the decreased leaf area index (LAI), the shading effect of the trees is still necessary in the east-west street of Lhasa. The average temperature of the measuring point 4 (under the shade) on the south side of the road is slightly higher than that of the measuring point 5, suggesting that the trees are beneficial to improve the thermal environment of the Lhasa street in winter when the solar radiation is low. The relative humidity and average wind speed of the two measuring points 2 and 4 under the shade are lower than that of the measuring point 3 and 5, indicating that the greening reduces the relative humidity on both sides of the road and has a certain effect on weakening the wind speed. The solar radiation on the Duosen Road is more uniform. By comparing the other two pairs of measuring points, it can be seen that the temperature and relative humidity are not significantly different, but the wind speed fluctuates greatly, suggesting the effect of trees on the street thermal environment is not significant.

    The impacts of greening on street thermal environment of different sides of the same street were compared. The measuring point 2 (under the shade) and 3 on the north side of the east-west Yutuo Road, the measuring point 4 (under the shade) and 5 on the south side of the road, the measuring point 6 and 7 (under the shade) on the west side of the south-north Duosen Road, the measuring point 8 (under the shade of the tree) and 9 on the east side of the road were compared pairwise to obtain the difference value between the two points (Figure 7a, b). The analysis can be obtained.

    Figure 7a.  Measured drawing of measuring points on the different sides of the same street.
    Figure 7b.  Measured drawing of measuring points on the different sides of the same street.

    By comparing the air temperature, solar radiation value, black sphere temperature, average radiation temperature, relative humidity and average wind speed of two pairs of points on Yutuo Road. It can be found that in summer, the thermal environment of the north side is better than that of the south side, and the cooling effect of the trees increases the time in a comfortable state, and the influence of trees on the north side with a large amount of radiation and no shielding of buildings is greater. In winter, the air temperature, black sphere temperature, average radiation temperature, and solar radiation value on the north side of the road are much larger than that on the south side. The measuring point 3 can achieve a "hot" thermal sensation, while the time of "comfortable" thermal sensation of the point 2 under the shade is the longest. Due to the lack of solar radiation on the south side of the road, the thermal sensation at the measuring point 4, 5 is mainly cold, very cold, and the PET at the measuring point 4 under the shade is slightly higher than that at the measuring point 5. The trees also have a more significant impact on the north side of the road. By comparing the average wind speed on both sides, it can be known the average wind speed on the south side is larger than that on the north side, and the trees have a greater influence on the wind speed on the south side.

    By comparing the air temperature, solar radiation value, black sphere temperature, average radiation temperature and relative humidity of the two pairs of measuring points on the South Duosen Road. It can be found that the thermal environment on the east side is better than that on the west side in summer, and no significant difference can be found in the influence of trees on the thermal environment on both sides of the street. The wind speed variation of each measuring point fluctuates greatly without obvious law. Generally speaking, trees have a certain blocking effect on wind speed. In winter, the solar radiation value and relative humidity on the west side of the road are greater than that on the east side, and the time in the "comfortable state" is also longer, but no significant difference can be found in the influence of trees on the thermal environment on both sides of the street.

    The impacts of greening on thermal environment of streets with different directions were compared, and each measuring point on the east-west Yutuo Road and the north-south Duosen Road were analyzed. By comparing the overall average temperature, solar radiation value, black sphere temperature value of the two streets in summer and winter, it can be obtained that the overall air temperature of Yutuo Road is higher than that of Duosen Road, and the time of PET in the "comfortable" thermal sensation is also longer, indicating that the thermal environment of east-west street is obviously not as good as that of the north-south street.The average radiation temperature of each measuring point was calculated by the formula. The average radiation temperature of the measuring points under the shade on Yutuo Road is significantly lower than that of the unshaded measuring points, while the tree shade has little impact on the changes of average radiation temperature on the Duosen Road, demonstrating the cooling effect of tree shade on the east-west street shade is greater than that on the north-south street. By comparing the average humidity of the two streets, it is concluded that the average humidity of Yutuo Road is lower than that of Duosen Road. In summer, the humidity under the shade is higher than that in area without shade, while in winter it shows opposite trend, and the impact of greening on Yutuo Road is greater than that on Duosen Road. There is no obvious law of wind speed at each measuring point, and the change is significant. Due to the shielding of trees, the wind speed is slightly reduced, but there is no obvious law of the influence on streets with different directions.

    The impacts of trees with different leaf area index (LAI) on street thermal environment were compared. The measuring point 4 (under the shade) and 5 on Yutuo Road, point 10 and 11 (under the shade) on the south side of the Hongqi Road were compared pairwise. The LAI of the tree at the measuring point 4 is larger, and the difference between the two pairs of measuring points is compared (Figure 8 below). The analysis can be obtained.

    Figure 8.  Measured drawing of measuring points under trees with different leaf area index.

    In summer, the air temperature, solar radiation value, black sphere temperature and average radiation temperature at the measuring point 4 and 11 under the trees are lower than that at the measuring point 5 and 10 outside the shade, and the measuring point 4 shows lower temperature, larger relative humidity, and longer PET value in a "comfortable" thermal sensation, it is suggested that the increase in LAI is beneficial to cool the street and increase humidity.

    In winter, because the measuring point 4, 5, 10, and 11 are located on the south side of the east-west street, the amount of solar radiation is less throughout the day, so they are all in a state of "cold" and "coll". The temperature at point 4 with larger LAI under the tree is the highest in the whole day, and the measuring points under the tree with a small LAI has little effect on the thermal comfort. The humidity of Yutuo Road is less than that of Hongqi Road, and the trees play a humidifying role, while the influence of trees on Hongqi Road is not obvious. It can also be seen from the picture above that the LAI at measuring point 4 is larger than that at measuring point 11, and the blocking effect on the wind speed is also more obvious.

    The arrangement form of water area in the selected street is only fountain, which is only open in summer. Therefore, the measurement was conducted in summer only. The measuring point 1 near the fountain on the north side of the Yutuo Road and measuring point 3 without tree shade on the same side of the same street were selected for comparison, as shown in Figure 9 below. The analysis can be obtained: The two measuring points are both located on the north side of Yutuo Road, so the variation curve of wind speed at both points are consistent without significant difference, indicating that the water area has no evident impact on improving wind speed. Since there is no tree shading at both measuring points, the solar radiation value is large, the air temperature, black sphere temperature, and average radiation temperature are also high with consistent curves, but the temperature at the measuring point 1 is slightly lower than that at measuring point 3 and the time in a "comfortable" thermal sensation is longer. The flowing fountain at the measuring point 1 evaporates quickly and the relative humidity is greater than that at measuring point 3, demonstrating that the water area can exert a certain cooling and humidifying effect on the street thermal environment in summer.

    Figure 9.  Analysis diagram of measured water points.

    In order to further study the effect of water and trees on the improvement of thermal environment in summer, in this paper, the variance analysis of SPSS software and Paired sample T-test were used to quantify the cooling effect of street trees and fountain. Through data analysis, it can be found that the cooling effect of fountains (C1, 3) is lower than that of trees (C2, 3) in the east-west street of Yutuo Road, while comparing the cooling effect of trees in the South (C5, 6) and North (C3, 4) of Yutuo Road, it is found that the cooling effect of trees in the south is not as obvious as that in the north. This is related to the SVF of the trees in the two measuring points. The SVF of the north measuring point is slightly larger than that of the south measuring point, resulting in the reduction of the solar radiation in the north side greater than that in the south measuring point. Moreover, the cooling effect of trees on the north-south direction of Duosen Road is obviously not as strong as that on the east-west direction of Yutuo Road, which also shows that the cooling effect of trees is more obvious in the case of worse thermal environment. In the Table 5, ΔTa, Δ Tmrt, ΔPET and ΔSR refer to the influence of greening and water area on air temperature, average radiation temperature, physiological equivalent temperature and solar radiation in different streets of Lhasa.

    Table 5.  Analysis of cooling effect of trees and water.
    Comparative factors △Ta(℃) △Tmrt(℃) △PET(℃) △SR (W.m−2)
    Mean ± S.E.Mean Mean ±S.E.Mean Mean ±S.E.Mean Mean ± S.E.Mean
    C1, 3 2.28 ± 0.95* 6.17 ± 1.18* 4.51 ± 0.91* /
    C2, 3 8.73 ± 0.64* 15.22 ± 1.45* 12.62 ± 1.10* 453.35 ± 87.7*
    C4, 5 5.96 ± 0.78* 13.1 ± 1.66* 10.06 ± 1.25* 389.97 ± 76.50*
    C6, 7 1.02 ± 0.29* 0.51 ± 0.27* 1.12 ± 0.30* 252.93 ± 65.74*
    C8, 9 2.04 ± 0.30* 2.85 ± 0.45* 3.0 ± 0.36* 73.67 ± 73.55*
    Note: *p is significant within 0.05.

     | Show Table
    DownLoad: CSV

    The correlation coefficient R2 = 0.824 (P < 0.05). It also shows the cooling effect of trees. Previous studies have highlighted the role of tree shadow on street microclimate, but also pointed out the limitations of its role.

    Figure 10.  Correlation analysis of daytime average temperature and solar radiation of each measuring point in summer.

    Through the field research on the streets of Lhasa and the actual measurement of the impact of the underlying surface design elements on the thermal environment of Lhasa Street, the main conclusions are as follows:

    (1) In summer, the solar radiation intensity has a great influence on the street thermal environment. The surface temperature under the shade is much lower than the surface temperature without shade, and the temperature difference can reach 24 ℃. In the winter, on the south side of the east-west street with poor thermal environment, the surface temperature under the shade is slightly higher than the surface temperature outside the shade. On the north-south street, the trend is opposite. It shows that trees can improve the thermal environment in winter.

    In the winter, the measured results show that the north side of the east-west street can achieve a "hot" thermal sensation when there is no tree shade, and the time in a "comfortable" thermal sensation is less than 30 minutes. The time in "comfortable" thermal sensation under the shade is the longest, for four and a half hours, suggesting that the tree shade is necessary on the north side of the east-west streets in Lhasa. Due to the lack of solar radiation on the south side of east-west street, the buildings play a shielding role throughout the day. The main thermal sensations are "cool", "slightly cold" and "cold", and the tree has little effect on the improvement of the thermal environment. There is little difference in the thermal comfort on north-south street with shade or without shade.

    (2) On the east-west street, the cooling effect of the trees on the south side is not as obvious as that on the north side. On the north-south street, there is no significant difference in the cooling effect of trees between both sides.

    (3) The thermal environment of the east-west streets of Lhasa is inferior than that of the north-south streets in summer and winter. The cooling effect of trees on the north-south Duosen Road is obviously not strong as that of the east-west Yutuo Road, and the trees exert the most obvious cooling effect in summer on the east-west streets, which also shows that the cooling effect of the trees is more prominent in the poor thermal environment.

    (4) The tree leaf area index (LAI) also has an effect on the improvement of the street thermal environment, and the increased leaf area index is more beneficial for improving the street microclimate.

    (5) The water area can improve the thermal environment of the street in summer, but the cooling effect is inferior to that of trees.

    This research was supported by National Natural Science Foundation Research on the Optimization and Design of Urban Social Living Space on the Tibetan Plateau Based on Microclimate Improvement. (No.51578453).

    Finally, all authors declare that there is no conflict of interest in this article, submissions have not been published in other journals, and fully agree that the manuscript will be considered to be published in AIMS Press journal in Open Access Format.

    [1] Dagdeviren C, Joe P, Tuzman OL, et al. (2016) Recent progress in flexible and stretchable piezoelectric devices for mechanical energy harvesting, sensing and actuation. Extreme Mech Lett 9: 269–281. doi: 10.1016/j.eml.2016.05.015
    [2] Mohebbi A, Mighri F, Ajji A, et al. (2018) Cellular polymer ferroelectret: A review on their development and their piezoelectric properties. Adv Polym Tech 37: 468–483. doi: 10.1002/adv.21686
    [3] Harrison JS, Ounaies Z (2002) Piezoelectric polymers, In: Encyclopedia of Polymer Science and Technology, 474–498.
    [4] Mohebbi A, Mighri F, Ajji A, et al. (2015) Current issues and challenges in polypropylene foaming: A review. Cell Polym 34: 299–337.
    [5] Hamdi O, Mighri F, Rodrigue D (2018) Optimization of the cellular morphology of biaxially stretched thin polyethylene foams produced by extrusion film blowing. Cell Polym [In press].
    [6] Zhai W, Wang H, Yu J, et al. (2008) Cell coalescence suppressed by crosslinking structure in polypropylene microcellular foaming. Polym Eng Sci 48: 1312–1321. doi: 10.1002/pen.21095
    [7] Rachtanapun P, Selke SEM, Matuana LM (2004) Effect of the high‐density polyethylene melt index on the microcellular foaming of high‐density polyethylene/polypropylene blends. J Appl Polym Sci 93: 364–371. doi: 10.1002/app.20428
    [8] Rachtanapun P, Selke SEM, Matuana LM (2004) Relationship between cell morphology and impact strength of microcellular foamed high‐density polyethylene/polypropylene blends. Polym Eng Sci 44: 1551–1560. doi: 10.1002/pen.20152
    [9] Huang HX (2005) HDPE/PA-6 blends: Influence of screw shear intensity and HDPE melt viscosity on phase morphology development. J Mater Sci 40: 1777–1779. doi: 10.1007/s10853-005-0692-x
    [10] Huang HX, Jiang G, Mao SQ (2005) Effect of flow fields on morphology of PP/Nano/CaCO3 composite and its rheological behavior. ASME International Mechanical Engineering Congress and Exposition,Orlando, Florida, USA, 80830: 567–574.
    [11] Huang HX, Wang JK, Sun XH (2008) Improving of cell structure of microcellular foams based on polypropylene/high-density polyethylene blends. J Cell Plast 44: 69–85. doi: 10.1177/0021955X07086082
    [12] Ding J, Shangguan J, Ma W, et al. (2013) Foaming behavior of microcellular foam polypropylene/modified nano calcium carbonate composites. J Appl Polym Sci 128: 3639–3651.
    [13] Wang C, Ying S, Xiao Z (2013) Preparation of short carbon fiber/polypropylene fine-celled foams in supercritical CO2. J Cell Plast 49: 65–82. doi: 10.1177/0021955X12459642
    [14] Zheng WG, Lee YH, Park CB (2010) Use of nanoparticles for improving the foaming behaviors of linear PP. J Appl Polym Sci 117: 2972–2979.
    [15] Mohebbi A, Mighri F, Ajji A, et al. (2017) Effect of processing conditions on the cellular morphology of polypropylene foamed films for piezoelectric applications. Cell Polym 36: 13–34.
    [16] Audet E (2015) Films cellulaires en polypropylène chargé de talc et de carbonate de calcium utilisés comme matériaux piézoélectriques: optimisation de la structure cellulaire par étirage bi-axial et par gonflement sous atmosphère d'azote [Thesis]. Laval University.
    [17] Wegener M, Wirges W, Fohlmeister J, et al. (2004) Two-step inflation of cellular polypropylene films: void-thickness increase and enhanced electromechanical properties. J Phys D Appl Phys 37: 623–627. doi: 10.1088/0022-3727/37/4/013
    [18] Sborikas M, Wegener M (2013) Cellular-foam polypropylene ferroelectrets with increased film thickness and reduced resonance frequency. Appl Phys Lett 103: 252901.
    [19] Qiu X, Xia Z, Wang F (2007) Piezoelectricity of single-and multi-layer cellular polypropylene film electrets. Front Mater Sci China 1: 72–75. doi: 10.1007/s11706-007-0013-1
    [20] Rychkova D, Altafim RAP, Qiu X, et al. (2012) Treatment with orthophosphoric acid enhances the thermal stability of the piezoelectricity in low-density polyethylene ferroelectrets. J Appl Phys 111: 124105.
    [21] An Z, Zhao M, Yao J, et al. (2009) Improved piezoelectric properties of cellular polypropylene ferroelectrets by chemical modification. Appl Phys A-Mater 95: 801–806.
    [22] Padasalkar GG, Shaikh JM, Syed YD, et al. (2015) A Review on Piezoelectricity. IJAREEIE 4: 8231–8235.
    [23] Pandey A, Shukla S, Shukla V (2015) Innovation and application of piezoelectric materials: a theoretical approach. IJATES 3: 1413–1417.
    [24] Li W, Torres D, Diaz R, et al. (2017) Nanogenerator-based dual-functional and self-powered thin patch loudspeaker or microphone for flexible electronics. Nat Commun 8: 15310.
    [25] Curie J, Curie P (1880) Development by pressure of polar electricity in hemihedral crystals with inclined faces. Bull Soc Min de France 3: 90–93.
    [26] Defay E (2013) Dielectricity, Piezoelectricity, Pyroelectricity and Ferroelectricity, In: Defay E, Integration of Ferroelectric and Piezoelectric Thin Films: Concepts and Applications for Microsystems, Great Britain and United States: ISTE Ltd and John Wiley & Sons, Inc., 1–24.
    [27] Setter N, Damjanovic D, Eng L, et al. (2006) Ferroelectric thin films: Review of materials, properties, and applications. J Appl Phys 100: 051606. doi: 10.1063/1.2336999
    [28] Abraham CS (2011) A review of ferroelectric materials and their applications. Ferroelectrics 138: 307–309.
    [29] Graz I, Mellinger A (2016) Polymer Electrets and Ferroelectrets as EAPs: Fundamentals, In: Carpi F, Electromechanically Active Polymers. Polymers and Polymeric Composites: A Reference Series, Springer, Cham.
    [30] Kirjavainen K (1987) Electromechanical film and procedure for manufacturing same. U.S. Patent, No: 4654546.
    [31] Savolainen A, Kirjavainen K (1989) Electrothermomechanical film. Part I. Design and characteristics. J Macromol Sci A 26: 583–591.
    [32] Rychkov D, Altafim RAP (2016) Polymer Electrets and Ferroelectrets as EAPs: Models, In: Carpi F, Electromechanically Active Polymers. Polymers and Polymeric Composites: A Reference Series, Springer, Cham.
    [33] Hillenbrand J, Sessler G, Zhang X (2005) Verification of a model for the piezoelectric d33 coefficient of cellular electret films. J Appl Phys 98: 0641051.
    [34] Sessler GM, Hillenbrand J (1999) Electromechanical response of cellular electrets films. Appl Phys Lett 75: 3405–3407. doi: 10.1063/1.125308
    [35] Zhanh H (2010) Scale-up of extrusion foaming process for manufacture of polystyrene foams using carbon dioxide [Thesis]. University of Toronto.
    [36] Wegener M (2010) Piezoelectric polymer foams: transducer mechanism and preparation as well as touch-sensor and ultrasonic-transducer properties. Proceedings Volume 7644, Behavior and Mechanics of Multifunctional Materials and Composites, 76441A.
    [37] Hossieny N (2010) Morphology and properties of polymer/carbon nanotube nanocomposite foams prepared by super critical carbon dioxide [Thesis]. The Florida State University.
    [38] Nawaby AV, Zhang ZY (2004) Solubility and Diffusivity, In: Gendron R, Thermoplastic Foam Processing: Principles and Development. Boca Raton, FL: CRC Press, 1–42.
    [39] Kumar V, Suh NP (1990) A Process for Making Microcellular Thermoplastic Parts. Polym Eng Sci 30: 1323–1329. doi: 10.1002/pen.760302010
    [40] Kumar V, Weller JE, Montecillo R (1992) Microcellular PVC. J Vinyl Technol 14: 191–197. doi: 10.1002/vnl.730140406
    [41] Schirmer HG, Kumar V (2003) Novel reduced-density materials by solid-state extrusion: Proof-of-concept experiments. Cell Polym 23: 369–385.
    [42] Park CB, Cheung LK (1997) A study of cell nucleation in the extrusion of polypropylene foams. Polym Eng Sci 37: 1–10. doi: 10.1002/pen.11639
    [43] Park CB, Suh NP (1996) Filamentary extrusion of microcellular polymers using a rapid decompressive element. Polym Eng Sci 36: 34–48.
    [44] Chen L, Rende D, Schadler LS, et al. (2013) Polymer nanocomposite foams. J Mater Chem A 1: 3837–3850. doi: 10.1039/c2ta00086e
    [45] Colton JS, Suh NP (1986) The nucleation of microcellular thermoplastic foam: process model and experimental results. Adv Manuf Process 1: 341–364. doi: 10.1080/10426918608953169
    [46] Colton JS, Suh NP (1987) The nucleation of microcellular thermoplastic foam with additives: Part I: Theoretical considerations. Polym Eng Sci 27: 485–492. doi: 10.1002/pen.760270702
    [47] Colton JS, Suh NP (1987) The nucleation of microcellular thermoplastic foam with additives: Part II: Experimental results and discussions. Polym Eng Sci 27: 493–499. doi: 10.1002/pen.760270703
    [48] Bae SS (2005) Preparation of polypropylene foams with micro/nanocellular morphology using a Sorbitol-based nucleating agent [Thesis]. University of Toronto.
    [49] Liu F (1998) Processing of polyethylene and polypropylene foams in rotational molding [Thesis]. University of Toronto.
    [50] Shi J (2017) Ferro-electrets material in human body energy harvesting [Thesis]. University of Southampton.
    [51] Gerhard-Multhaupt R (2002) Less can be more. Holes in polymers lead to a new paradigm of piezoelectric materials for electret transducers. IEEE T Dielect El In 9: 850–859.
    [52] Bauer S, Gerhard-Multhaupt R, Sessler GM (2004) Ferroelectrets: Soft electroactive foams for transducers. Phys Today 57: 37–43.
    [53] Ramadan KS, Sameoto D, Evoy S (2014) A review of piezoelectric polymers as functional materials for electromechanical transducers. Smart Mater Struct 23: 1–26.
    [54] Qiu X, Gerhard R, Mellinger A (2011) Turning polymer foams or polymer-film systems into ferroelectrets: dielectric barrier discharges in voids. IEEE T Dielect El In 18: 34–42. doi: 10.1109/TDEI.2011.5704490
    [55] Qiu X, Mellinger A, Wegener M, et al. (2007) Barrier discharges in cellular polypropylene ferroelectrets: How do they influence the electromechanical properties. J Appl Phys 101: 104112. doi: 10.1063/1.2735410
    [56] Qiu X, Mellinger A, Gerhard R (2008) Influence of gas pressure in the voids during charging on the piezoelectricity of ferroelectrets. Appl Phys Lett 92: 052901. doi: 10.1063/1.2841037
    [57] Montanari GC, Mazzanti G, Ciani F, et al. (2004) Effect of gas expansion on charging behavior of quasi-piezoelectric cellular PP. The 17th Annual Meeting of the IEEE Lasers and Electro-Optics Society, 153–157.
    [58] Zhang P, Xia Z, Qiu X, et al. (2005) Influence of charging parameters on piezoelectricity for cellular polypropylene film electrets. 12th International Symposium on Electrets, 39–42.
    [59] Koliatene F (2009) Contribution à l'étude de l'existence des décharges dans les systèmes de l'avionique 'Contribution to the study of the existence of discharges in avionics systems' [Thesis]. Toulouse University.
    [60] Wegener M, Tuncer E, Gerhard-Multhaupt R, et al. (2006) Elastic properties and electromechanical coupling factor of inflated polypropylene ferroelectrets. 2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena, 752–755.
    [61] Tuncer E, Wegener M (2006) Soft polymeric composites for electro-mechanical applications: predicting and designing their properties by numerical simulations, In: Dillon KI, Soft Condensed Matter: New Research, Nova Science publishers, 217–275.
    [62] Gibson LJ, Ashby M (1997) Cellular Solids: structure and properties, In: Solid state science, Cambridge University Press.
    [63] Lindner M, Hoislbauer H, Schwodiaue R, et al. (2004) Charged cellular polymers with ferroelectretic behavior. IEEE T Dielect El In 11: 255–263. doi: 10.1109/TDEI.2004.1285895
    [64] Xu BX, von Seggern H, Zhukov S, et al. (2013) Continuum modeling of charging process and piezoelectricity of ferroelectrets. J Appl Phys 114: 094103. doi: 10.1063/1.4819441
    [65] Torquato S (2001) Random Heterogeneous Materials: Microstructure and macroscopic properties, New York: Springer Science & Business Media.
    [66] Tuncer E (2005) Numerical calculations of effective elastic properties of two cellular structures. J Phys D Appl Phys 38: 497–503. doi: 10.1088/0022-3727/38/3/023
    [67] Qui X (2016) Polymer Electrets and Ferroelectrets as EAPs: Materials, In: Carpi F, Electromechanically Active Polymers. Polymers and Polymeric Composites: A Reference Series, Springer, Cham.
    [68] Thyssen A, Almdal K, Thomsen EV (2015) Electret Stability Related to the Crystallinity in Polypropylene. 2015 IEEE Sensors, 1–4.
    [69] Fang P (2010) Preparation and Investigation of Polymer-Foam Films and Polymer-Layer Systems for Ferroelectrets [Thesis]. University of Potsdam.
    [70] Mellinger A, Wegener W, Wirges W, et al. (2006) Thermal and Temporal Stability of Ferroelectret Films Made from Cellular Polypropylene/Air Composites. Ferroelectrics 331: 189–199. doi: 10.1080/00150190600737933
    [71] Nakayama M, Uenaka Y, Kataoka S, et al. (2009) Piezoelectricity of ferroelectret porous polyethylene thin film. Jpn J Appl Phys 48: 09KE05.
    [72] Tajitsu Y (2011) Piezoelectric properties of ferroelectret. Ferroelectrics 415: 57–66. doi: 10.1080/00150193.2011.577372
    [73] Brañaa GO, Segoviab PL, Magranera F, et al. (2011) Influence of corona charging in cellular polyethylene film. J Phys Conf Ser 301: 012054. doi: 10.1088/1742-6596/301/1/012054
    [74] Mellinger A, Wegener M, Wirges W, et al. (2011) Thermally stable dynamic piezoelectricity in sandwich films of porous and nonporous amorphous fluoropolymer. Appl Phys Lett 79: 1851–1854.
    [75] Altafim RAP, Qiu X, Wirges W, et al. (2009) Template-based fluoroethylenepropylene piezoelectrets with tubular channels for transducer applications. J Appl Phys 106: 014106.
    [76] Wirges W, Wegener M, Voronina O, et al. (2007) Optimized preparation of elastically soft, highly piezoelectric cellular ferroelectrets from nonvoided poly(ethylene terephthalate) films. Adv Funct Mater 17: 324–329. doi: 10.1002/adfm.200600162
    [77] Wegener M, Wirges W, Dietrich JP, et al. (2005) Polyethylene terephthalate (PETP) foams as ferroelectrets. 12th International Symposium on Electrets, 28–30.
    [78] Fang P, Wegener M, Wirges W, et al. (2007) Cellular polyethylene-naphthalate ferroelectrets: foaming in supercritical carbon dioxide, structural and electrical preparation, and resulting piezoelectricity. Appl Phys Lett 90: 192908. doi: 10.1063/1.2738365
    [79] Fang P, Wirges W, Wegener M, et al. (2008) Cellular polyethylene-naphthalate films for ferroelectret applications: foaming, inflation and stretching, assessment of electromechanically relevant structural features. E-Polymers 8: 487–495.
    [80] Fang P, Qiu X, Wirges W, et al. (2010) Polyethylene-naphthalate (PEN) ferroelectrets: cellular structure, piezoelectricity and thermal stability. IEEE T Dielect El In 17: 1079–1087. doi: 10.1109/TDEI.2010.5539678
    [81] Li Y, Zeng C (2013) Low-temperature CO2-assisted assembly of cyclic olefin copolymer ferroelectrets of high piezoelectricity and thermal stability. Macromol Chem Phys 214: 2733–2738. doi: 10.1002/macp.201300440
    [82] Information of the company Xonano smart foam (USA). Available from: http://www.xonano.com/.
    [83] Dobkin BH, Dorsch A (2011) The promise of mHealth: Daily activity monitoring and outcome assessments by wearable sensors. Neurorehab Neural Re 25: 788–798. doi: 10.1177/1545968311425908
    [84] Patel S, Park H, Bonato P, et al. (2012) A review of wearable sensors and systems with application in rehabilitation. J Neuroeng Rehabil 9: 1–17. doi: 10.1186/1743-0003-9-1
    [85] Li X, Fisher M, Rymer WZ, et al. (2015) Application of the F-response for estimating motor unit number and amplitude distribution in hand muscles of stroke survivors. IEEE T Neur Sys Reh 24: 674–681.
    [86] Jarrasse N, Nicol C, Touillet A, et al. (2017) Classification of phantom finger, hand, wrist, and elbow voluntary gestures in transhumeral amputees with sEMG. IEEE T Neur Sys Reh 25: 71–80. doi: 10.1109/TNSRE.2016.2563222
    [87] Fang P, Ma X, Li X, et al. (2018) Fabrication, structure characterization, and performance testing of piezoelectret-film sensors for recording body motion. IEEE Sens J 18: 401–412. doi: 10.1109/JSEN.2017.2766663
    [88] Information of the company Emfit (Finland). Available from: https://www.emfit.com/.
    [89] Wegener M, Wirges W (2004) Optimized electromechanical properties and applications of cellular polypropylene-a new voided space-charge electret material, In: Fecht HJ, Werner M, The nano-micro interface: Bridging the micro and nano worlds, Wiley-VCH Verlag GmbH & Co. KGaA, 303–317.
    [90] Kim JY (2013) Parylene C as a new piezoelectric material [Thesis]. California Institute of Technology.
    [91] Saarimaki E, Paajanen M, Savijarvi A, et al. (2006) Novel heat durable electromechanical film: processing for electromechanical and electret applications. IEEE T Dielect El In 13: 963–972. doi: 10.1109/TDEI.2006.247820
    [92] Doring J, Bovtun V, Bartusch J, et al. (2010) Nonlinear electromechanical response of the ferroelectret ultrasonic transducers. Appl Phys A-Mater 100: 479–485. doi: 10.1007/s00339-010-5752-7
    [93] Lei W (2017) Ferroelectret nanogenerator (FENG) for mechanical energy harvesting and self-powered flexible electronics [Thesis]. Michigan State University.
    [94] Information of the company B-Band (Finland). Available from: http://www.b-band.com/.
    [95] Kogler A, Buchberger G, Schwodiauer R, et al. (2011) Ferroelectret based Flexible Keyboards and Tactile Sensors. 14th International Symposium on Electrets, 201–202.
    [96] Hillenbrand J, Kodejska M, Garcin Y, et al. (2010) High sensitivity piezoelectret film accelerometers. IEEE T Dielect El In 17: 1021–1027. doi: 10.1109/TDEI.2010.5539670
    [97] Hillenbrand J, Haberzettl S, Motz T, et al. (2011) Electret accelerometers: physics and dynamic characterization. J Acoust Soc Am 129: 3682–3687. doi: 10.1121/1.3585833
    [98] Information of 2020 armor products (USA). Available from: http://www.2020armor.com/.
    [99] Zhuo Q, Tian L, Fang P, et al. (2015) A piezoelectric-based approach for touching and slipping detection in robotic hands. 2015 IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems (CYBER), 918–921.
    [100] Ning C, Zhou Z, Tan G, et al. (2018) Electroactive polymers for tissue regeneration: Developments and perspectives. Prog Polym Sci 81: 144–162. doi: 10.1016/j.progpolymsci.2018.01.001
    [101] Wan YP, Zhong Z (2012) Effective electromechanical properties of cellular piezoelectret: A review. Acta Mech Sinica 28: 951–959. doi: 10.1007/s10409-012-0125-4
  • This article has been cited by:

    1. Wenjing Sun, Lixing Chen, Baimu Suolang, Kai Liu, An Investigation of the Energy-Saving Optimization Design of the Enclosure Structure in High-Altitude Office Buildings, 2024, 14, 2075-5309, 645, 10.3390/buildings14030645
    2. Elif Nur Sarı, Andre Santos Nouri, Mert Ekşi, Andreas Matzarakis, Assessing thermo-physiological effects of different tree species within the inner regions of the urban canyon; confronting in-situ extreme heat stress in Istanbul during the El-Niño summer of 2023, 2025, 0020-7128, 10.1007/s00484-025-02922-7
    3. Yiqun Li, Xiao Liu, Ali Cheshmehzangi, Leila Mohaghegh Zahed, Bao-Jie He, Multidimensional factors affecting tree-induced cooling benefits: A comprehensive review, 2025, 03601323, 113242, 10.1016/j.buildenv.2025.113242
  • Reader Comments
  • © 2018 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索