A calibration of E-field probe based on tissue-equivalent liquid waveguide and evaluation of uncertainty

China Academy of Information and Communications Technology, Beijing 100191, China

Special Issues: Machine Learning and Big Data in Medical Image Analysis

For the accuracy of Specific Absorption Rate (SAR) measurement, there is a need to have the measuring instrument, the E-field probe, calibrated on a regular basis, however, the conventional calibration approach can be complicated for an encapsulated dosimestic E-field probe. This paper proposed a new method to obtain the conversion factor of the E-field probe in the simulant tissue. The novelty of this proposal is that it can simplify the procedure of the conversion factor analysis, by employing the liquid waveguide with known E-filed as a component of the reference field to compare with the measured E-field of the dosimestic probe immersed in the equivalent-tissue liquid. Also, this paper evaluated the uncertainty of calibration for this method.
  Figure/Table
  Supplementary
  Article Metrics

References

1. IEEE Std C95.1-2005, IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz. 2005.

2. IEEE Std 1528, IEEE recommended practice for determining the peak spatial-average specific absorption rate (SAR) in the human head from wireless communications devices: Measurement techniques, Sept. 2013.

3. IEC Std 62209-1, Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz). 2016.

4. IEC Std 62209-2, Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures-Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz). 2010.

5. ICNIRP, International Commission on Non-Ionizing Radiation Protection. Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). 1998.

6. ISO/TS 14253-3, Geometrical product specifications (GPS)-Inspection by measurement of workpieces and measuring equipment-Part 3: Guidelines for achieving agreements on measurement uncertainty statements. 2002.

7. K. Poković, "Advanced electromagnetic porbe for near-field evaluations," ph.D. dissertation, Swiss Federal Institute of Technology, Zurich, Switzerland, 1999.

8. H. I. Bassen and G. S. Smith, Electric field probes-A Review, IEEE Transact. Anten. Propagat., 31 (1983), 710–718.

9. S. Pirbhulal, H. Y. Zhang, W. Q. Wu, et al., Heartbeats based biometric random binary sequences generation to secure wireless body sensor networks, IEEE Transact. Biomed. Eng. 65 (2018), 2751–2759.

10. W. Q. Wu, S. Pirbhulal, H. Y. Zhang, et al., Quantitative assessment for self-tracking of acute stress based on triangulation principle in a wearable sensor system, IEEE J. Biomed. Health Inform. 99 (2018), 1.

11. S. Pirbhulal, H. Y. Zhang, S. Mukhopadhyay, et al., An efficient biometric-based algorithm using heart rate variability for securing body sensor networks, Sensors, 15 (2015), 15067–15089.

12. S. Pirbhulal, H. Y. Zhang, M. E. E. Alahi, et al., A novel secure IoT-based smart home automation system using a wireless sensor network, Sensors, 17 (2017), 69.

13. W. Q. Wu, H. Y. Zhang, S. Pirbhulal, et al., Assessment of biofeedback training for emotion management through wearable textile physiological monitoring system, IEEE Sensors J., 15 (2015), 7087–7095.

14. H. Viltanen, J. Keshvari and R. Lappalainen, Interaction of radio frequency electromagnetic fields and passive metallic implants-A brief review, Bioelectromagnetics, 27(2006), 431–439.

15. V. Hombach, K. Meier, M. Burkhardt, et al., The dependence of EM energy absorption on human head modeling at 900 MHz, IEEE Transact. Microwave Theor. Techn, 44 (1996), 1865–1873.

16. A. Kyriacou, A. Christ, E. Neufeld, et al., Maximum Local Tissue Temperature Increase by Implanted Medical Devices Due to Electromagnetic Field Exposure, Bioelectromagnetics Annual Meeting, Seoul, Korea, June 2010.

17. L. Aberbour, B. Derat and A. Cozza, Analysis of vector E-field sensor array for real-time SAR assessment, Proceedings of European Conference on Antenna and Propagation (EuCAP), 2013.

18. K. Poković, T. Schmid and N. Kuster, Millimeter-resolution E-field probe for isotropic measurement in lossy media between 100 MHz and 20 GHz, IEEE Transact. Instrum. Meas., 49 (2000), 873–878.

19. T. Iyama, K. Kiminami and T. Onishi, Applicability of three-axis electro-optic (EO) probe for specific absorption rate (SAR) measurement. IEICE Transact. Commun., 92 (2009), 1414–1417.

20. O. Merckel, G. Fleury and J. C. Bolomey, Rapid SAR measurement via parametric modeling. In 5th International Congress of the European Bioelectromagnetics Association, Helsinki, Finland, September 2001.

21. C. C. Davis and Q. Balzano, The international intercomparison of SAR measurements on cellular telephones, IEEE Trans. Electromagn. Compat., 51 (2009), 210–216.

© 2019 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution Licese (http://creativecommons.org/licenses/by/4.0)

Download full text in PDF

Export Citation

Article outline

Show full outline
Copyright © AIMS Press All Rights Reserved