Research article Special Issues

Research on the applicability of passive house technology in areas hot in summer and cold in winter-take Nanjing area as the research object

  • Received: 05 September 2019 Accepted: 12 November 2019 Published: 03 December 2019
  • In this study, to explore the applicability of passive house technology under PHPP assessment standards in Chinese areas hot in summer and cold in winter, Nanjing area was taken as an example, real cases were examines under PHPP assessment standards for passive houses in line with regional climatic differences. The present study focused on four aspects, namely the thermal insulation & heat preservation properties of the external enclosure structure, the mildew-growing temperature of the interior wall, the air-tightness property of the external enclosure structure, as well as the damp-proof performance of buildings. A numeric analysis was conducted using Dest software, and the German PHPP assessment standards for passive houses were eventually found not entirely applicable to Chinese areas hot in summer and hot in winter. Thermal insulation, damp-proof, and vapor-proof properties should be considered when designing passive house projects for such areas. Based on influential factors, this study proposed the climatically-reconstructed design for the external enclosure structure of passive houses and employed Energyplus for demonstration and analysis. Analytical findings suggested that the reconstruction plan is feasible.

    Citation: Shenwei Yu, Mengqiu Yang. Research on the applicability of passive house technology in areas hot in summer and cold in winter-take Nanjing area as the research object[J]. AIMS Environmental Science, 2019, 6(6): 460-471. doi: 10.3934/environsci.2019.6.460

    Related Papers:

  • In this study, to explore the applicability of passive house technology under PHPP assessment standards in Chinese areas hot in summer and cold in winter, Nanjing area was taken as an example, real cases were examines under PHPP assessment standards for passive houses in line with regional climatic differences. The present study focused on four aspects, namely the thermal insulation & heat preservation properties of the external enclosure structure, the mildew-growing temperature of the interior wall, the air-tightness property of the external enclosure structure, as well as the damp-proof performance of buildings. A numeric analysis was conducted using Dest software, and the German PHPP assessment standards for passive houses were eventually found not entirely applicable to Chinese areas hot in summer and hot in winter. Thermal insulation, damp-proof, and vapor-proof properties should be considered when designing passive house projects for such areas. Based on influential factors, this study proposed the climatically-reconstructed design for the external enclosure structure of passive houses and employed Energyplus for demonstration and analysis. Analytical findings suggested that the reconstruction plan is feasible.


    加载中


    [1] John B (2019) Passive House Canada actively pursues Eastern Canada growth. Daily Commercial News 92: 150.
    [2] Wang HT, Liu YJ (2016) A discussion about Zhongde Energy Conservation Demonstration Project of Shenyang Jianzhu University. Constr Budget 12: 50-52.
    [3] Wang CL, Chu HL, Wang HT (2016) A study on the heat transmission coefficient of external walls in passive buildings with ultra-low energy consumption. Building Ener Eff 44: 65-67.
    [4] Wan CL, Wang HT, Shan B, et al. (2015) A testing analysis of the performances of external windows in passive houses with ultra-low energy consumption. Building Technol 19: 34-36.
    [5] Wang HT, Hou P, Weng D (2013) China Society for Environmental Sciences, Collection of Outstanding Papers of Environmental Protection for Puhua of Academic Annual Conference of CSES [C]. China Society for Environmental Sciences.
    [6] Ji YC, Wang ZJ, Su XW (2019) A study on the heat exchange performance experiment of radiating floor slabs of passive houses in extremely cold regions. Gas & Heat 39: 16-22.
    [7] Wang ZJ, Ji YC, Xue QW, et al. (2018) A study on the indoor environment of passive houses in ultra-low energy consumption in winter of extremely cold areas. HAVC 48: 66-70.
    [8] Wangn ZJ, Xue QW, Yu ZY, et al. (2017) A test and analysis of heat exchange efficiency of passive houses with ultra-low energy consumption in extremely cold areas. Building Sci 33: 21-25.
    [9] Nanjing Bureau of Statistics (2010) Nanjing Statistical Yearbook, Beijing: China Statistics Press.
    [10] Yu SW (2019) A study on the architectural energy conservation and reconstruction strategies based on BIM technology. Hubei University of Architecture.
    [11] Cai Q, Zhang ZR, Xie F, et al. (2017) D-23 residential public service project-an engineering case of architectural projects with ultra-low energy consumption in Beijing. Const Sci Technol 17: 39-41.
    [12] Liu JP (2009) Construction physics. 4 Eds. Beijing: China Building Industry Press.
    [13] Yu SW, Wang JK (2018) A study on the heat transmission coefficient of aerated concrete building blocks under the moisture state. J Bohai Univ (Natural Sciences) 39: 309-314.
    [14] China Academy of Building Research (2016) Design Specifications for Thermal Engineering of Civilian Buildings. Beijing: China Building Industry Press, 1-75.
  • Reader Comments
  • © 2019 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0)
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Metrics

Article views(2844) PDF downloads(406) Cited by(0)

Article outline

Figures and Tables

Figures(3)  /  Tables(5)

Other Articles By Authors

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return

Catalog