Design of sensor and actuator fault tolerant control system on wind turbine benchmark for Region II

Department of Engineering Physics, Institute of Technology Sepuluh Nopember, Surabaya, East Java, Indonesia

The control system performance of the wind turbine can be unexpected due to the minor fault of its components, such as bias fault in its speed sensor and its converter system. Indeed, the lack of treatment to these faults lead to major problem. This paper discusses the control system design of generator rotor speed that is tolerant of faulty sensors and actuators. The studied wind turbine benchmark is operated in Region II. The controller is developed based on a torque control scheme which generates control signal based on the generator speed measurement using proportional–integral (PI) algorithm. The sensor and actuator faults estimates are obtained by an extended state observer which realizes a new state from a filtered signal of the measurement. Then the sensor fault estimate is submitted to a compensation mechanism in order to correct measurement value while the actuator fault estimate is used to reconfigure control signal value in order to correct control signal.
  Figure/Table
  Supplementary
  Article Metrics

Keywords speed sensor; converter; observer; fault tolerant control

Citation: Katherin Indriawati, Bambang L. Widjiantoro, Ali Musyafa. Design of sensor and actuator fault tolerant control system on wind turbine benchmark for Region II. AIMS Energy, 2019, 7(2): 111-126. doi: 10.3934/energy.2019.2.111

References

  • 1. Secretariat of WWINDEA (2009) World Energy Report 2009.WWINDEA Organization, Bonn Germany.
  • 2. Noura H, Theilliol D, Ponsart JC, et al. (2009) Fault-tolerant Control Systems: Design and Practical Applications, London: Springer-Verlag.
  • 3. Campos-Delgado DU, Martinez Martinez S, Zhou K (2005) Integrated fault-tolerant scheme for a DC speed drive. IEEE/ASME T Mechatronics 10: 419–427.    
  • 4. Sami M, Patton R (2012) Wind turbine power maximization based on adaptive sensor fault tolerant sliding mode control. In The 20th Mediterranean conference on control and automation (MED12).
  • 5. Odgaard PF, Stoustrup J, Nielsen R, et al. (2009) Observer based detection of sensor faults in wind turbines. In Proceedings of European wind energy conference, 4421–4430.
  • 6. Sami M, Patton R (2012) An FTC approach to wind turbine powermaximisation via T-S fuzzy modelling and control. IFAC Safeprocess.
  • 7. Simani S, Castaldi P (2014) Active actuator fault-tolerant control of a wind turbine benchmark model. Int J Robust Nonlinear Control 24: 1283–1303.    
  • 8. Chen L, Shi F, Patton R (2013) Active FTC for hydraulic pitch system for an off-shore wind turbine. Conf. Control Fault-Tolerant Syst. (SysTol), Nice, France.
  • 9. Rotondo D, Nejari F, Puig V, et al. (2012)Fault tolerant control of the wind turbine benchmark using virtual sensors/actuators. IFAC Safeprocess.
  • 10. Simani S, Castaldi P (2012) Adaptive fault-tolerant control design approach for a wind turbine benchmark. IFAC Safeprocess.
  • 11. Odgaard PF, Stoustrup J (2015) A benchmark evaluation of fault tolerant wind turbine control concepts. IEEE T Control Syst Technol 23: 1221–1228.    
  • 12. Indriawati K, Sebe N, Agustinah T, et al. (2015) Robust Fuzzy Observer-based Fault Tolerant Tracking Control for Nonlinear Systems with Simultaneous Actuator and Sensor Faults: Application to a DC Series Motor Speed Drive. Int Rev Autom Control 8: 375–385.
  • 13. Liu X, Gao Z, Chen MZQ (2017) Takagi–Sugeno fuzzy model based fault estimation and signal compensation with application to wind turbines. IEEE T Ind Electron 64: 5678–5689.    
  • 14. Shi F, Patton R (2015) An active fault tolerant control approach to an offshore wind turbine model. Renew Energ 75: 788–798.    
  • 15. Indriawati K, Agustinah T, Jazidie A (2015) Robust Observer-based Fault Tolerant Tracking Control for Linear Systems with Simultaneous Actuator and Sensor Faults: Application to a DC Motor System. Int Rev Model Simul 8: 410–417.
  • 16. Odgaard PF, Stoustrup J, Kinnaert M (2013) Fault-tolerant control of wind turbines: A benchmark model. IEEE T Contr Syst T 21: 1168–1182.    
  • 17. Pintea A, Pepescu D, Borne P (2010) Modeling and control of wind turbines. 12th Sysmposium Large Scale systems Theory and App, France.
  • 18. Heier S (1998) Grid Integration of wind energy conversion systems, NJ: John Wiley & Sons Ltd.

 

Reader Comments

your name: *   your email: *  

© 2019 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution Licese (http://creativecommons.org/licenses/by/4.0)

Download full text in PDF

Export Citation

Copyright © AIMS Press All Rights Reserved